EPEVER Milwaukee Power Inverter 3000Watt DC 24V AC Output 110V Solar Power Inverters IP3000-21-Plus(T)
IPower-Plus Power Inverter is a new generation of pure sine wave inverter compatible with the lithium battery system.
Milwaukee Power Inverter Overview
IPower-Plus is a new generation of pure sine wave inverter compatible with the lithium battery system. This new inverter adopts surge current suppression technology to effectively prevent the surge current from damaging the lithium battery cells and BMS
(Battery Management System). Also, adopting the voltage and current double closed-loop control algorithm brings the inverter a faster response and better resistance to the load impact. The inverter selects key components with a high power density and long lifespan to
provide a stable and reliable power guarantee. The optional communication solutions allow users to monitor the real-time status or change the parameters wherever. The inverter can be widely used in DC to AC areas, such as solar AC power system, vehicle system, RV
power supply, security monitoring system, emergency lighting system, field power system, household power system, etc. With an excellent EMC (Electro Magnetic Compatibility) characteristic, the 24V inverter is also suitable for occasions with high power quality requirements.
Milwaukee Power Inverter Features:
- Completely electrically isolated design for input and output
- Full digital double closed-loop control
- Excellent EMC characteristic, widely applied to higher quality power system
- Advanced SPWM technology and pure sine wave output.
- Input surge current suppression technology, applying to the lithium battery system
- Outstanding load resistance to impact, applying to the air conditioners, washing machines, refrigerators, etc.
- High power density and high-quality components to ensure the reliability
- Output power factor up to 1
- Low loss of zero loads and standby. Low THD (Total Harmonic Distortion). High conversion efficiency
- Extensive protections: input reverse polarity/under voltage/over voltage, output overload/short circuit/overheating
- Air cooling is controlled by temperature and load
- Rotatable LCD meter to simplify the system wiring
- Friendly LCD meter to simply monitor and parameter configure
- Remote control by the phone Apps and PC software
- Configurable output voltage and output frequency①
- Charging mobile phones, DC fans, and other electrical equipment by the USB port②
- Support a variety of options by connecting with the RS485 com. port③
- External switch contact design to allow remote control
- IEC62109, EN61000, RoHS approved
① Configuring the parameters via the local LCD meter, remote LCD meter, phone Apps, and PC software.
② This function is unavailable for inverters with 48V input voltage.
③ There is no communication isolation design for inverters with 12V/24 input voltage. This function(communication isolation design) is just for inverters with 48V input voltage.

3000W Pure Sine Wave Inverter 24V to 110V Parameters
Continuous output power | 3000W@35℃@Rated input voltage |
Surge power | 6000W@5S |
Surge current when power on | <100A |
Output voltage | 110VAC(±3%); 120VAC(-7%~+3%) |
Output frequency | 50/60Hz±0.2% |
Output wave | Pure Sine Wave |
Output distortion THD | THD≤5%(Resistive load) |
Load power factor | 0.2~1(VA≤output continuous power) |
Rated input voltage | 24VDC |
Input voltage range | 21.6~32.0VDC |
No-load current | <1A |
USB output | 5VDC/Max.1A |
RS485 com. port | 5VDC/ 200mA |
Dimension | 521×274×148mm |
Mounting dimension | 495×145mm (Mounting Holes: Φ6mm) |
Net Weight | Net Weight 8kg |
- Battery wire size: 25mm2/3AWG*2
- Battery Circuit breaker: DC-100A(2P in parallel)
- AC Wire size: 6mm2/10AWG
- AC Circuit breaker: AC/2P—50A
- Outstanding load resistance to impact, applying to the air conditioners, washing machines, refrigerators, etc.
- Charging mobile phones, DC fans, and other electrical equipment by the USB port
Milwaukee Power Inverter Note:
- It is recommended to connect the inverter DC input terminal to the battery terminal directly. DO NOT connect it to the charge source terminal. Otherwise, the charging voltage spikes of the charge source may cause over-voltage protection of the inverter.
- The AC loads shall be determined by the continuous output power of the inverter. The AC load's surge power must be lower than the instantaneous surge power of the inverter, or the inverter will be damaged.
- Set the inverter switch to OFF status before wiring.
- During wiring, do not close the circuit breaker or fuse. Ensure the leads of "+" and "-" poles are polarity correctly.
- A fuse whose current is 2 to 2.5 times the inverter's rated current must be installed on the battery end. Distance between them is not more than 150mm.
- When supplying power for different loads, it is recommended to turn on the load with a large impulse current. And then turn on the load with a smaller impulse current after the load output is stable.)
- If the fault indicator flashes red and the buzzer alarms after powering on the inverter, please immediately turn off the load and the inverter. Clear the faults according to Chapter 8 Troubleshooting.
Parameters | IP3000-21-Plus(T) | IP3000-12-Plus(T) |
Continuous output power | 3000W@35℃@Rated input voltage | |
Surge power | 6000W@5S | 6000W@5S |
Surge current when power on | <100A | <100A |
Output voltage | 110VAC(±3%); | 220VAC(±3%); |
120VAC(-7%~+3%) | 230VAC(-7%~+3%) | |
Output frequency | 50/60Hz±0.2% | |
Output wave | Pure Sine Wave | |
Output distortion THD | THD≤4%(Resistive load) | THD≤3%(Resistive load) |
Load power factor | 0.2~1(VA≤output continuous power) | |
Rated input voltage | 24VDC | 12VDC |
Input voltage range | 21.6~32.0VDC | 10.8~16.0VDC |
Rated output efficiency① | >87% | >87% |
Max. output efficiency② | >91.5% (30%loads) | >94% (30% loads) |
Idle current | <0.15A | <0.2A |
No-load current | <1A | <1.6A@12V |
USB output | 5VDC/Max.1A | 5VDC/Max.1A |
RS485 com. port | 5VDC/ 200mA | |
Mechanical parameters | ||
Input terminal | M6 | M10 |
Dimension (Length x Width x Height) | 521×274×148mm | 557×231.5×123mm |
Mounting dimension | 495×145mm | 532×145mm |
Mounting Holes | Φ6mm | Φ6mm |
Net Weight | 8kg | 10.5kg |
Working temperature | -20℃~+60℃(Refer to the Reduced capacity curve) | |
Relative humidity | < 95%(N.C.) | |
Enclosure | IP20 | |
Altitude | <5000m (If the altitude is more than 1000 meters, the rated power will be reduced according to GB7260.) | |
① It means the rated output efficiency when the load power is continuous output power under the rated DC input voltage. (25℃ )
② It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage. |
IPower-Plus Power Inverter is a new generation of pure sine wave inverter compatible with the lithium battery system.
This new pure sine inverter adopts surge current suppression technology to effectively prevent the surge current from damaging the lithium battery cells and BMS (Battery Management System). Also, adopting the voltage and current double closed-loop control algorithm brings the inverter a faster response and better resistance to the load impact. The 24V inverter selects key components with a high power density and long lifespan to provide a stable and reliable power g. The optional communication solutions allow users to monitor the real-time status or change the parameters wherever. The inverter can be widely used in DC to AC areas, such as solar AC power system, vehicle system, RV power supply, security monitoring system, emergency lighting system, field power system, household power system, etc. With an excellent EMC (Electro Magnetic Compatibility) characteristic, the inverter is also suitable for occasions with high power quality requirements.
Features:
- Advanced SPWM technology and pure sine wave output.Completely electrically isolated design for input and output
- Excellent EMC characteristic, widely applied to higher quality power system
- Input surge current suppression technology, applying to the lithium battery system
- Outstanding load resistance to impact, applying to the air conditioners, washing machines, refrigerators, etc.
- Output power factor up to 1
- Low loss of zero loads and standby. Low THD (Total Harmonic Distortion). High conversion efficiency
- Air cooling controlled by temperature and load
- Rotatable LCD meter, to simply monitor and parameter configure.
- Remote control by the phone Apps and PC software
- Configurable output voltage and output frequency (Configuring the parameters via the local LCD meter, remote LCD meter, phone Apps, and PC software.)
- Charging mobile phones, DC fans, and other electrical equipment by the USB port
- External switch contact design to allow remote control
- Extensive protections: input reverse polarity/under voltage/over voltage, output overload/short circuit/overheating. IEC62109, EN61000, RoHS approved
3000W Pure Sine Wave Inverter 24V to 110V Parameters
>td >Load power factor
Continuous output power | 3000W@35℃@Rated input voltage |
Surge power | 6000W@5S |
Surge current when power on | <100A |
Output voltage | 110VAC(±3%); 120VAC(-7%~+3%) |
Output frequency | 50/60Hz±0.2>#/td### |
Output wave | Pure Sine Wave |
Output distortion THD | |
0.2~1(VA≤output continuous power) |
Rated input voltage | 24VDC |
Input voltage range | 21.6~32.0VDC |
No-load current | <1A |
USB output | 5VDC/Max.1A |
RS485 com. port | 5VDC/ 200mA |
Dimension | 521×274×148mm |
Mounting dimension | 495×145mm (Mounting Holes: Φ6mm) |
Net Weight | Net Weight 8kg |
- Battery wire size: 25mm2/3AWG*2
- Battery Circuit breaker: DC-100A(2P in parallel)
- AC Wire size: 6mm2/10AWG
- AC Circuit breaker: AC/2P—50A
- Outstanding load resistance to impact, applying to the air conditioners, washing machines, refrigerators, etc.
- Charging mobile phones, DC fans, and other electrical equipment by the USB port
Note:
- It is recommended to connect the inverter DC input terminal to the battery terminal directly. DO NOT connect it to the charge source terminal. Otherwise, the charging voltage spikes of the charge source may cause over-voltage protection of the inverter.
- >span class="a-list-item">Set the inverter switch to OFF status before wiring.
- During wiring, do not close the circuit breaker or fuse. Ensure the leads of "+" and "-" poles are polarity correctly.
- A fuse whose current is 2 to 2.5 times the inverter's rated current must be installed on the battery end. Distance between them is not more than 150mm.
- When supplying power for different loads, it is recommended to turn on the load with a large impulse current. And then turn on the load with a smaller impulse current after the load output is stable.)
- If the fault indicator flashes red and the buzzer alarms after powering on the inverter, please immediately turn off the load and the inverter. Clear the faults according to Chapter 8 Troubleshooting.
- 24V
- Lifepo4 Batteries
- Lithium Batteries
- Flooded Batteries
- Gel Batteries
- AGM Batteries
- High frequency Inverters
- 110/120Vac±5%
- 3000W