GTI-600W On Grid Tie Inverter Input DC18V Output 230V AC MPPT Function 600W 99% Efficiency Pure Sine Wave for Solar Energy Systems
GTI-600W MPPT On Grid Tie Inverter Input DC18V Output 230V AC Function 600W 99% Efficiency Pure Sine Wave for Solar Energy Systems
Feature:
- Unique circuit design, choice of import industrial electronic components, higher efficiency, more stable performance.
- Creative MPPT technology, efficiency more than 99%, faster and more sensitive reaction, more reliable.
- Parallel type design for DC input and modularization design for inverter, small volume, distributed installation, easy for system configuration, flexible for combination, strong expansibility of system.
- Adopting high-frequency isolation transformer type, high efficiency, and high security.
- Perfect electrical protection function.
- Aluminum alloy housing, not rust, heat-resisting, and cold-resistant as well as anti-corrosion.
- Getting electronic circuit design, appearance design, and other core technology patents.
Electronic protections:
- Low-voltage protection (DC input voltage lower than Min. input voltage of inverters).
- Over-voltage protection (DC input voltage higher than Max. input voltage of inverters).
- Over-temperature protection (inverters will shut down for power output when the temperature of the body of inverters is higher than 65-75°C, and inverters will automatically restart up when temperature down to 40-50°C.).
- Power grid fault protection when 110VAC or 220VAC grid power outage and/or tripped.
- Islanding protection: inverter will be automatically shut down for power output when disconnect from the power grid.
- Short-circuit protection: inverter stops work when output line short-circuits.
Package Included:
- 1x Grid Tie inverter
- 1x Cable
Please confirm the specification before install
Rated Power | 600Watt |
Solar Panels | (18Vpv) 36cells-Vmp:18-21V:Voc:20-24V |
DC Input Range | 11-32VDC |
MPPT Voltage | 15-22VDC |
DC MAX. Current | 38A |
AC Output | 120VAC(90-140VAC) or 230VAC(190-260VAC) |
Frequency | 50Hz/60Hz(Auto control) |
Power Factor | >98% |
THD | <5% |
Phase Shift | <2% |
Efficiency | 120VAC(90-140VAC) Version |
Peak Efficiency | 85 |
Stable Efficiency | 86 |
Efficiency | 230VAC(190-260VAC) Version |
Peak Efficiency | 86 |
Stable Efficiency | 88 |
Protection | Islanding; Short-circuit; Low Voltage; Over Voltage; Over temperature Protection |
Working Temperature | ‘-20℃-65℃ |
Working Humidity | 0%~90%RH non-condensing |
Waterproof | Indoor design |
Show | Luminous Diode(LED) |
Cooling | Fan |
Stand-by Power | <1W |
EMC | EN61000-6-3:2007 EN61000-6-1:2007 |
Grid Disturbance | EN 50178+EN 62109-1+VDE0126-1-12 |
Grid Detection | DIN VDE 1026 UL1741 |