MPPT solar charge controller are based on an advanced maximum power point tracking (MPPT) technology developed, dedicated to the solar system, the charge controller conversion efficiency up to 98%.
A: time (night working) B: period (pause) C: time slot (dawn working)
Installing wires, first loosen the screw counterclockwise
Model |
K60
|
K80
|
K100
|
Maximum power current |
60A
|
80A
|
100A
|
Load output power |
40A
|
40A
|
40A
|
Installation Lin(mm2) |
18
|
20
|
20
|
Installation Line(AWG) |
6#
|
4#
|
4#
|
Weight |
2100g
|
2300g
|
2300g
|
Peak power of solar cell panel(Max Wp) |
≤800
|
≤1040
|
≤1300
|
Battery capacity configuration |
≥600AH
|
≥800AH
|
≥800AH
|
Dimensions |
300*200*100(mm)
|
||
Original Value | |||
Battery float voltage |
13.8V(12V system) / 27.6V(24V system)
|
||
Battery (under voltage) protection |
10.6V(12V system) / 21.2V(24V system)
|
||
Battery (under voltage) recovery voltage |
12.6V(12V system) / 25.2V(24V system)
|
||
System load loss: ≤13mA |
Loop Buck: ≤100mV
|
||
Operating Temperature:-10℃~60℃ |
Storage Temperature: -30℃~70℃
|
||
Humidity requirements:≤90%, No condensation |
Temperature compensation: -4mV/Cell/℃
|
||
Maximum open circuit voltage of the solar panel |
18V-48V(12V system)/36V-96V
(24V system)
|
||
Solar panels maximum open circuit voltage (V) |
≤96V
|
Q | Why when I hook up my 5 24v solar panels after I connect the batteries to the charger and it started smoking why |
A | ARE YOUR PANELS IN PARALLEL OR SERIES? IF IN SERIES IT IS TOO MUCH VOLTAGE. 5 X 24 = 120 VOLTS, IN PARALLEL IT WOULD BE THE 24 VOLT YOU NEED, LOOK AT THE CIRCUIT BOARD AND SEE WHAT WAS SMOKING. YOU MAY BE ABLE TO REPLACE THAT PART AND GET IT TO WORK BUT I AM AFRAID YOU ARE STUCK WITH A DEAD CONTROLLER. IT WILL NOT BE REPLACED IF YOU DID NOT FOLLOW THE DIRECTIONS IN THE INSTALLING OF IT.. CONTACT THE SELLER TO SEE WHAT TO DO see less |
Q | Can this be used with lifepo4 batteries |
A | No,it only support leasd-acid battery(seal,gel,agm,flooded) |
Q | The switch to 24v automatically |
A | Please connect the battery before connecting the solar panel, otherwise the high voltage of the solar panel will be recognized as the system voltage. |
Q | Is there a setting to inform the unit of the type of battery in use? |
A | Is there a setting to inform the unit of the type of battery in use? |
Q | I have four 340 w panels. vmp 38.2v, imp 8.9a, voc 46.2v, isc 9.5a. two 100 ah 12v batteries. can this controller handle them all? |
A | Dear friend, |
Q | Can I use for 9 panel of 300w ? |
A | If your system is 2V syteam, you can use it。 But the total input voltage of the solar panel does not exceed 96V (25℃) |
Q | Can this controller be used for lithium batteries? |
A | Hifreind, it can't! it's only for lead acid batteries. |
The following controllers can support lithium batteries | |
Q | Can these charge controllers be hooked up in parallel to handle more amperage? |
A | NO |
Q | If panel is 24v will it charge one 12v battery |
A | i can not tell you about that but i have a 12 volt panel that puts out more than 12 volts but it charges up to 13.8 volts on my batteries . it works well for me. |
Q | Can I use Lifepo4 batteries w this? |
A | No, it only support lead-acid battery. |
Q | What is the highest battery shutdown voltage for a 24 volt hookup? |
A | 27.6 VDC |
Q | When battery load is greater than charge current, pacer charger will lose mppt and charge current drop to 10% before load.would this unit do the same? |
A | Please check whether the battery voltage is lower than the low-voltage disconnect voltage |
Q | What would cause my gel cell batterys to drain down from 80% to 60% when the solar stops charging? It 12v system mppt |
A | Dear friend, |
How much power load do you connect? After your battery is fully charged, can the battery stay at 13.6V after standing for 4 hours? | |
Could you please contact us va email: ysolar@foxmail.com ? | |
Looking forward you reply | |
Q | Is this controller waterproof? |
A | No,It is not waterproof. |
We have other waterproof 15A and 5A controllers | |
see less | |
Q | I don’t know much about this but I need a controller because I plan to create a system with 8 batteries 12v115ah ant 280w solar panel .can I use this? |
A | Yes, you can use it. but if you only 280W solar panel, 30A mppt charge controller is enough |
Q | What is the highest battery shutdown voltage for a 24 volt hookup? |
A | The float voltage of the 24V system can be set to 28.8V, that is, when the battery voltage is stable at 28.8v, it indicates that the battery is fully charged. |
Just make sure that the maximum input power and voltage are not exceeded. | |
Please always connect the battery before connect the solar panel, and disconnect in reverse oreder | |
Q | will the load terminal power my 180watt fan thats rated at 15 amps? |
A | Yes |
Q | What would cause the green light on the controller to not light up? |
A | green light? this controller no green light. could you please feel free to contact us via email: ysolar@foxmail.com ? |
(please provide some picture and your system parameter ) | |
Q | What does "power terminals: 10 awg" mean? |
A | That the power terminal is designed to fit to a conducting wire the diameter of 10 awg. |
Q | Can I use it on othet battery types beside Lead Acid batteries? |
A | Dear friend, it can support lead Acid batteries, incloud AGM, GEL, Sealed, Flooded. But not support lithium Battery. |
Q | What is the long black wire for? |
A | Temperature probe, one end is connected to the controller, the other end is attached to the battery |
temperature compensation increase your battery life and improve your system's performance | |
Q | does this have a coil inside? |
A | Yes, it have. Please look at the fourth picture of the product link. |
Q | Is it really designed for a positive ground? Will using it on a RV with the standard negative ground still work ok? |
A | Dear friend, |
It is really positive ground, not use for negative ground. Please buy a negative ground. | |
The Tracer AN series is negative controller | |
Best wishes | |
Q | Is there a manual or web site to tell you how to program the controller? |
A | a. Short press the first toggle button on the left though the data till you see the parameter which you want to modify. |
b. when the data blinking, Short Press + -- to adjust the parameter | |
c.Just wait 5 second Or switch to another parameter will Automatic save | |
Q | How is it a 60amp controller but you can only fit a 10awg cable in it? You need a bigger cable for 60amps |
A | If the unit puts out pulses of DC current it will lower the average current as a function of time on /total time times 100 percent |
This is the duty cycle calculation for pulse width modulation | |
Q | For 60a unit, is it really 100v open circuit max for panels or 48v? top text says 100v, but lower section says 48v. |
A | Dear friend, |
At 25℃ temperature Maximum open circuit voltage of the solar panel (Voc): 18V-48V(When in 12V system) / 36V-96V (When in 24V system) . It is best to use temperature probe for temperature compensation | |
Best wishes, | |
Q | Can these charge controllers be hooked up in parallel to handle more amperage? |
A | Dear, You can connect 2 or 4 this charge controller to the batteries bank in parallel, but do not share PV Panels. Dedicate a number of PV panels to each controller. |
Max Input Power: 12V battery @ 750W | 24V @ 1500W | |
Max.PV open circuit voltage:12V @ 48V | 24V @ 96V | |
Please alwasys connect the battery before connect the solar panel, disconnect in reverse order. | |
DO NOT connect any inverters or battery charger into the load terminal of the charge controller. | |
A fuse which current is 1.25 to 2 times the rated current of the controller, must be installed on the battery side with a distance from the battery not greater than 150 mm. | |
Best wishes |
- Administrator reply
- Hello, our service will contact u soon.
- Administrator reply
- Hello, our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will reply to you soon
- Administrator reply
- Our service will reply to you soon
Our company makes delivery all over the world
We only offer quality goods with higher cost performance
You have 30 days to test your purchase