GLN-BT 51.2V 200Ah LiFePO4 10.24KWh Deep Cycle Super Battery Life

$2,69415
In stock
+

Minimum quantity for "GLN-BT 51.2V 200Ah LiFePO4 10.24KWh Deep Cycle Super Battery Life" is 2.

Why PowMr?
  • — Fast Delivery
  • — Free Shipping 
  • — 24 months warranty 
  • — Avg. response time 1 Hrs. (Working  Day)
  • PowMr Everywhere 
Wholesale

GLN-BT 51.2V 200Ah LiFePO4 10.24KWh Deep Cycle Super Battery Life

Overview:

NO

Projects

Specification

Remark

Cell unit parameter

1

Battery types and materials

LiFePO4

 

2

Rated voltage/capacity

3.2V/200Ah

 

3

Single battery voltage range

2.5V3.65V

 

4

Single battery weight

4.0Kg

 

5

The battery's internal resistance

≤ 0.4mΩ

 

6

Module size

174*54*201mmL*W*H

 

Battery parameter

1

Rated voltage

51.2V

 

2

Rated capacity

200Ah

 

3

Battery pack voltage range

43.2V58.4V

 

4

kWh

Total Power

10.24kWh

 

5

Combination

1P16S

 

6

(Ω)Insulation resistance test value

≥20MΩ

 

7

Operating temperature

Charging 0 ~ 50℃;

Discharging -20 ~ 55

 

8

Standard charging current

≤100A

Parallel version with 20A (charging current limit)

9

Standard discharge current

≤100A

 

10

Gross weight

88Kg

 

11

Battery Modle size

L510*W250*H520±2mm

 

12

Installation Method

Floor

 

13

communication

RS485/RS232

Optional

Product Electric Performance Test:

No.

Items

Test Conditions

Requirements

1

Open circuit voltage

Open circuit voltage measured within 24 hours after standard charge

≥51.2V

2

Impedance

Under the condition of full power, the AC impedance of AC1kHz is measured

≤20mΩ

 

3

Capacity retention

Fully charging, store them at (20±5) for 28 days, then discharge to 40.0V @0.2C.

≥300min

Discharging time≥300min

4

Cycle Life @25

Discharge to 40.0V @0.2C, then Charge the battery @0.2C to reach 58.4V. Then charge the battery at constant 58.4V voltage until the charging current decreasing to 0.02C. Rest for 10 min. discharge to 40.0V@ 0.2C and rest for 10 min.  Continue the charge/discharge cycles until discharge capacity lower than 80% of rated capacity.

Cycles life ≥2000

5

storage

Charge the battery to 40%~65% of its rated capacity using standard charging mode, then keep it in an 20±5, humidity 45%~85% room for 12 months, fully charge and discharge it @0.2C until voltage down .

(The testing sample should be within 3 months dated from production date)

≥300min

Discharge time≥300min


Please read the specification carefully before install: GLN-ED-067