PowMr All In One Inverter Charger 48V DC Output 220V AC 5000Watt Solar Inverter Charger POW-5KM-48
PowMr All In One Inverter Charger 48V DC Output 220V AC 5000Watt Solar Inverter Charger POW-5KM-48

Great backup power for your off-grid system! Get rid of the trouble of power outages!
This is a multi-function all in one inverter charger, combining functions of inverter, solar charger, and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Features
1.5KVA Pure sine wave inverter
2. Configurable input voltage range for home appliances and personal computers via LCD setting
3. Configurable battery charging current based on applications via LCD setting
4. Configurable AC/Solar Charger priority via LCD setting
5. Compatible with mains voltage or generator power
6. Auto restart while AC is recovering
7.Overload/ Over temperature/ short circuit protection
8. Smart battery charger design for optimized battery performance
9. Cold start function
- Low DC Warning Voltage @ load < 50% 46.0Vdc @ load ≥ 50% 44.0Vdc
- Low DC Warning Return Voltage @ load < 50% 47.0Vdc @ load ≥ 50% 46.0V dc
- Low DC Cut-off Voltage @ load < 50% 43.0Vdc@ load ≥ 50% 42.0Vdc
- High DC Recovery Voltage 62Vdc
- High DC Cut-off Voltage 63Vdc
- No Load Power Consumption <55W
- PV Array Open Circuit Voltage Max 145Vdc
Reminder: Only for US users
1. In the mains bypass mode, the device cannot be connected to two-phase 220V AC power, that is, L1-L2 cannot be connected to L-N.
2. In 48V inverter mode, after the device is connected to two-phase 220V, please do not select the mains priority as the output priority, so as to avoid potential safety hazards for the device.
3. Do not connect the AC output end of the device to an autotransformer, so as not to affect the normal service life of the device.
Note
1. Not for the 110V system!
2. Please read the instructions before using.
3. NEVER charge a frozen battery.
4. Please strictly follow the installation procedure when you want to disconnect AC or DC terminals.
5. Be very cautious when working with metal tools on or around batteries.
5KVA Inverter Specifications
Rated Output Power 5KVA/5KW
Output Voltage Waveform Pure Sine Wave
Output Voltage Regulation 230Vac±5>#/p###
Output Frequency 50Hz
Peak Efficiency93>#/p###
Overload Protection 5s@≥150% load; 10s@105%~150% load
Surge Capacity 2* rated power for 5 seconds
Nominal DC Input Voltage 48Vdc
Cold Start Voltage 46.0Vdc
Built-in 60A MPPT CONTROLLER
Packing list
5KVA Inverter x 1
Communication cable x 1
Software CD x 1
DC Fuse x 1
Ring terminal x 1
Strain relief plate x 2
Screws x 4
PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
When selecting proper PV modules, please be sure to consider the below parameters:
1. Open circuit Voltage (Voc) of PV modules does not exceed the max. PV array open-circuit voltage of the inverter.
2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
INVERTER MODEL 5KVA
Max. PV Array Open Circuit Voltage 145Vdc PV Array MPPT Voltage Range 60~115Vdc
Take the 250Wp PV module as an example. After considering the above two parameters, the recommended module configurations for 5KVA are listed as below:
Maximum Power (Pmax) 250W Max. Power Voltage Vmp(V) 30.1V
Max. Power Current Impp(A) 8.3A Open Circuit Voltage Voc(V) 37.7V Short Circuit Current Isc(A)8.4A
5KVA: 2 pieces in serial and 6 sets in parallel, or 3 pieces in serial and 4 sets in parallel
Pure Sine Wave technologyPure Sine Wave technology safely powers electronic devices by producing clean, stable, electricity that is just as dependable and safe as the power you get from home. | Cooling Fan DesignComes with an intelligent cooling fan, helps increase effectiveness as well as dissipate heat, to make your inverter work safer and more effective. | With LCD moduleIts comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications. |
PowMr 5KVA Hybrid Inverter
This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.
SPECIFICATIONS
Table 1 Line Mode Specifications
INVERTER MODEL |
1KVA |
2KVA |
3KVA |
3KVA Plus |
5KVA |
|||
Input Voltage Waveform |
Sinusoidal (utility or generator) |
|||||||
Nominal Input Voltage |
230Vac |
|||||||
Low Loss Voltage |
170Vac±7V (UPS); |
|||||||
Low Loss Return Voltage |
180Vac±7V (UPS); |
|||||||
High Loss Voltage |
280Vac±7V |
|||||||
High Loss Return Voltage |
270Vac±7V |
|||||||
Max AC Input Voltage |
300Vac |
|||||||
Nominal Input Frequency |
50Hz / 60Hz (Auto detection) |
|||||||
Low Loss Frequency |
40±1Hz |
|||||||
Low Loss Return Frequency |
42±1Hz |
|||||||
High Loss Frequency |
65±1Hz |
|||||||
High Loss Return Frequency |
63±1Hz |
|||||||
Output Short Circuit Protection |
Circuit Breaker |
|||||||
Efficiency (Line Mode) |
>95% ( Rated R load, battery full charged ) |
|||||||
Transfer Time |
10ms typical (UPS); 20ms typical (Appliances) |
|||||||
When AC input voltage drops to 170V, the output power will be derated. | ![]() |
Table 2 Inverter Mode Specifications
INVERTER MODEL | 1KVA | 2KVA | 3KVA | 3KVA Plus | 5KVA |
Rated Output Power | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW | 5KVA/5KW | |
Output Voltage Waveform | Pure Sine Wave | ||||
Output Voltage Regulation | 230Vac±5% | ||||
Output Frequency | 50Hz | ||||
Peak Efficiency | 93% | ||||
Overload Protection | 5s@≥150% load; 10s@105%~150% load | ||||
Surge Capacity | 2* rated power for 5 seconds | ||||
Nominal DC Input Voltage | 12Vdc | 24Vdc | 24Vdc | 48Vdc | |
Cold Start Voltage | 11.5Vdc | 23.0Vdc | 23.0Vdc | 46.0Vdc | |
Low DC Warning Voltage | 23.0Vdc | 46.0Vdc | |||
11.5Vdc | 23.0Vdc | ||||
Low DC Warning Return Voltage | 23.5Vdc | 47.0Vdc | |||
11.7Vdc | 23.5Vdc | ||||
Low DC Cut-off Voltage | 21.5Vdc | 43.0Vdc | |||
10.7Vdc | 21.5Vdc | ||||
High DC Recovery Voltage | 15Vdc | 30Vdc | 32Vdc | 62Vdc | |
High DC Cut-off Voltage | 16Vdc | 31Vdc | 33Vdc | 63Vdc | |
No Load Power Consumption | <25W | <55W |
Table 3 Charge Mode Specifications
Table 4 General Specifications
INVERTER MODEL | 1KVA | 2KVA | 3KVA | 3KVA Plus | 5KVA |
Safety Certification | CE | ||||
Operating Temperature Range | -10°C to 50°C | ||||
Storage temperature | -15°C~ 60°C | ||||
Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||||
Dimension (D*W*H), mm | 88 x 225 x 320 | 100 x 285 x 334 | 100 x 300 x 440 | ||
Net Weight, kg (PWM model) | 5.0 | 5.5 | 6.3 | N/A | 8.5 |
Net Weight, kg (MPPT model) | N/A | N/A | 6.5 | 9.5 | 9.7 |
- No Lithium Batteries Activation
- 48V
- Flooded Batteries
- Gel Batteries
- Lead-acid Batteries
- High frequency Inverters
- Single Phase
- 230Vac±5%
- 5000W
- 145V
- build-in MPPT Solar Charge Controller
- 3000W
- 60 Amps
- 60amps
- 120Amps
- Wifi Module(Optional)
Question: | Does this have a neutral bar to allow for only 110 legs to be used and/or may a neutral bar be added to allow such? kindest regards |
Answer: | Hi dear customer, this inverter is for 220v only, not for 110v. |
Question: | Can i connect 4x200 ah battery |
Answer: | Under normal circumstances it is possible, But we need more parameter values from you in order to give you better advice. You can email us at on:szpuhua_us@126.com, so and we will send you the technical specifications and guide. |
Question: | Does this hybrid injects in to the grid? |
Answer: | Hi dear customer, this inverter can not be connected to the grid. |
Question: | Can you set output Frequency to 60Hz? |
Answer: | Hi dear customer, yes you can set it to 60 HZ. |
No reviews found