- Administrator reply
- Hello, our service will contact u soon.
Growatt 7KW 100A 48v All In One Inverter Solar 220Vac Build-in 100Amps MPPT Charger Controller SPF 3500 ES *2
2PCS Growatt 7000W Solar Inverter Charger With MPPT 100A Solar Controller Battery Regulator DC 48V System Output AC 220V Max Input PV 450V Parallel 6 Unit Suitable lifepo4 Work with or Without Battery
Product description
Size:3.5KW-ES
Overview
This is a multifunctional off-grid solar inverter, integrated with an MPPT solar charge controller, a high-frequency pure sine wave inverter, and a UPS function module in one machine, which is perfect for off-grid backup power and self-consumption applications. This all in one inverter can work with or without batteries.
Features
- Rated power 3.5KW to 5KW, power factor 1
- MPPT ranges 120V~430V, 450Voc
- High-frequency 48V inverter with small size and lightweight
- Pure sine wave AC output
- Solar and utility grid can power loads at the same time
- With CAN/RS485 for BMS communication
- With the ability to work without a battery
- Parallel operation up to 6 units (only with the battery connected)
- WIFI/ GPRS remote monitoring (optional)
Growatt 3500ES Specifications
Nominal Input Voltage | 230Vac(Max AC Input Voltage:300Vac) |
Nominal Input Frequency | 50Hz / 60Hz (Auto-detection) |
Rated Output Power | 3.5KVA/3.5KW Pure Sine Wave |
Output Voltage Regulation | 230Vac±5>% |
Output Frequency | 50Hz |
Surge Capacity | 2* rated power for 5 seconds |
Nominal DC Input Voltage | 48Vdc |
Max. PV Array Power | 4500W |
Max. PV Input Current | 18A |
Start-up Voltage | 150Vdc±10Vdc |
PV Array MPPT Voltage Range | 120Vdc~430Vdc |
Max. PV Open Circuit Voltage | 450Vdc |
Max. PV Charging Current | 80A |
Max. AC Charging Current | 60Amp(@VI/P=230Vac) |
Operating Temperature Range | 0℃ to 55℃(131 °F) |
Output source working mode(To configure load power source priority)
| ![]() |
Charger source priority: To configure charger source priority
| ![]() |
IMPORTANT WIRING NOTE:
- Install screws recommend M4 or M5 size screws.
- Make sure the polarity at both the battery and the inverter/charge is correct.
- connected and ring terminals are tightly screwed to the terminals.
- Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to the negative(-).
- AC Input/Output recommended cable size: 10 AWG; PV recommended cable size: 12 AWG/1.2-1.6 Nm Torque value; Battery recommended cable: 4 AWG/2-3 Nm Torque value
- Parallel operation up to 6 units (only with the battery connected)
Specifications | ||
Table 1 Line Mode Specifications | ||
INVERTER MODEL | SPF 3500 ES | SPF 5000 ES |
Input Voltage Waveform | Sinusoidal (utility or generator) | |
Nominal Input Voltage | 230Vac | |
Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
High Loss Voltage | 280Vac±7V | |
High Loss Return Voltage | 270Vac±7V | |
Max AC Input Voltage | 300Vac | |
Nominal Input Frequency | 50Hz / 60Hz (Auto-detection) | |
Low Loss Frequency | 40±1Hz | |
Low Loss Return Frequency | 42±1Hz | |
High Loss Frequency | 65±1Hz | |
High Loss Return Frequency | 63±1Hz | |
Output Short Circuit Protection | Circuit Breaker | |
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) | |
Transfer Time | 10ms typical, 20ms Max@ Single <30ms @ Parallel | |
Table 2 Inverter Mode Specifications | ||
INVERTER MODEL | SPF 3500 ES | SPF 5000 ES |
Rated Output Power | 3.5KVA/3.5KW | 5KVA/5KW |
Output Voltage Waveform | Pure Sine Wave | |
Output Voltage Regulation | 230Vac±5% | |
Output Frequency | 50Hz | |
Peak Efficiency | 93>% | |
Overload Protection | 5s@≥150% load; 10s@110%~150% load | |
Surge Capacity | 2* rated power for 5 seconds | |
Nominal DC Input Voltage | 48Vdc | |
Cold Start Voltage(Lead-Acid Mode) | 46.0Vdc | |
Cold Start SOC(Li Mode) | Default 30%, Low DC Cut-off SOC +10% | |
Low DC Warning Voltage (Lead-Acid Mode) | 44.0Vdc @ load < 20% | |
42.8Vdc @ 20% ≤ load < 50% | ||
40.4Vdc @ load ≥ 50% | ||
Low DC Warning Return Voltage (Lead-Acid Mode) | 46.0Vdc @ load < 20% | |
44.8Vdc @ 20% ≤ load < 50% | ||
42.4Vdc @ load ≥ 50% | ||
Low DC Cut-off Voltage (Lead-Acid Mode) | 42.0Vdc @ load < 20% | |
40.8Vdc @ 20% ≤ load < 50% | ||
38.4Vdc @ load ≥ 50% | ||
Low DC Cut-off Voltage (Li Mode) | 42.0Vdc | |
Low DC Warning SOC (Li Mode) | Low DC Cut-off SOC +5% | |
Low DC Warning Return SOC (Li Mode) | Low DC Cut-off SOC +10% | |
Low DC Cut-off SOC(Li Mode) | Default 20%, 5%~30% settable | |
High DC Recovery Voltage | 56.4Vdc(C.V. charging voltage) | |
High DC Cut-off Voltage | 60.8Vdc | |
No Load Power Consumption | <60W | |
Table 3 Charge Mode Specifications | ||
Utility Charging Mode | ||
INVERTER MODEL | SPF 3500 ES | SPF 5000 ES |
Charging Algorithm | 3-Step | |
Max. AC Charging Current | 60Amp(@VI/P=230Vac) | 80Amp(@VI/P=230Vac) |
Bulk Charging Voltage Flooded Battery | 58.4Vdc | |
AGM / Gel Battery | 56.4Vdc | |
Floating Charging Voltage | 54Vdc | |
MPPT Solar Charging Mode | ||
Max. PV Array Power | 4500W | 6000W |
Max. PV Input Current | 18A | |
Start-up Voltage | 150Vdc±10Vdc | |
PV Array MPPT Voltage Range | 120Vdc~430Vdc | |
Max. PV Array Open Circuit Voltage | 450Vdc | |
Max. PV Charging Current | 80A | 100A |
Max. Charging Current (AC Charger Plus Solar Charger) | 80A | 100A |
Table 4 General Specifications | ||
INVERTER MODEL | SPF 3500 ES | SPF 5000 ES |
Safety Certification | CE | |
Operating Temperature Range | 0℃ to 55℃ | |
Storage temperature | -15℃~ 60℃ | |
Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
Altitude | <2000m | |
Dimension(D*W*H), mm | 485 x 330 x 135 | |
Net Weight, kg | 11.5 | 12 |
Brand information
Brand :
PowMr
Battery Information for inverters and controllers
Lithium Battery Activation :
- Active Lithium Batteries
Battery Voltage :
- 48V
Battery Type :
- Lifepo4 Batteries
- Lithium Batteries
- Flooded Batteries
- Gel Batteries
- Lead-acid Batteries
- AGM Batteries
Inverter Information
Inverter Type:
- High frequency Inverters
Load workout with Battery:
Yes
Parallel Function:
Yes
Phase:
- Single Phase
- Parallel Single for Three Phase
Split Phase:
No
AC output:
- 230Vac±5%
Rated Load Power:
- 3500W
Solar Panel Information for inverters
Max Panel Input Volt :
- 450V-500V
PV Terminal Charging Mode:
- build-in MPPT Solar Charge Controller
Max Solar Panel Input Power:
- 4500W
Charging Current Information for inverters
AC Charging Current:
- 60 Amps
PV Charging Current:
- 80amps
AC+PV Charging Current:
- 80Amps
Accessories information for inverters
Wifi/Bluetooth Module:
- Wifi Module(Optional)
Other Information
Warehouse:
- AUS Warehouse
- USA Warehouse
Q | Can this run my washer and dryer |
A | Because washing machines and dryers are inductive loads, the instantaneous power of starting is as high as 6-7 times. Therefore, we need you to provide the nameplate information of the washing machine and dryer, so that we can judge whether the solar inverter can drive your washing machine and dryer. |
Q | If I connct six inverters in series, what is the smallest AH of batteries that should be connected? |
A | It cannot be connected in series, only can be connected in parallel to the same battery pack. |
Q | Whats the best transformer to combo with this to obtain 120v a/c output if needed? |
A | Could you consider this inverse |
Abbey
United States