PowMr 12VDC 1KW All In One Solar Inverter Charger 40Amp MPPT Solar Charge Controller With LCD Display 220VAC Output Off-Grid Inverter Charger

Out of stock
BrandPowMr Lithium Battery Activation No Lithium Batteries Activation Battery Voltage12V Battery TypeFlooded Batteries, Gel Batteries, Lead-acid Batteries, User Mode PhaseSingle Phase Inverter TypeHigh frequency Inverters AC output230Vac±5% Rated Load Power1000W Max Panel Input Volt100V-150V PV Terminal Charging Modebuild-in MPPT Solar Charge Controller Max Solar Panel Input Power500W AC Charging Current20 Amps PV Charging Current40amps AC+PV Charging Current60Amps Wifi/Bluetooth ModuleWifi Module(Optional)
$24699

Minimum quantity for "PowMr 12VDC 1KW All In One Solar Inverter Charger 40Amp MPPT Solar Charge Controller With LCD Display 220VAC Output Off-Grid Inverter Charger" is 1.

Why PowMr?
  • — Fast Delivery
  • — 24 months warranty 
  • — Avg. response time 1 Hrs. (Working  Day)
  • PowMr Everywhere 
    Wholesale

    PowMr 12VDC 1KW Solar Inverter Charger 40Amp MPPT Solar Charge Controller With LCD Display 220VAC Output Off-Grid Inverter Charger

    Product Instruction:

    This is a multi-function all in one inverter charger, combining functions of inverter, solar charger, and battery charger to offer uninterruptable power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

    Features:

    • Brand: Powmr
    • Model: POW-1KM-12
    • Display Model: LCD Display
    • Technology Support: MPPT/PWM
    • Hybrid Model: Inverter/Charge
    • Pure sine wave inverter
    • Configurable input voltage range for home appliances and personal computers via LCD setting
    • Configurable battery charging current based on applications via LCD setting
    • Configurable AC/Solar Charger priority via LCD setting
    • Compatible to mains voltage or generator power
    • Auto restart while AC is recovering
    • Overload/ Over temperature/ short circuit protection
    • Smart battery charger design for optimized battery performance
    • Cold start function

    Reminder: Only for US users

    1. In the mains bypass mode, the device cannot be connected to two-phase 220V AC power, that is, L1-L2 cannot be connected to L-N.
    2. In inverter mode, after the device is connected to two-phase 220V, please do not select the mains priority as the output priority, so as to avoid potential safety hazards for the device.
    3. Do not connect the AC output end of the device to an autotransformer, so as not to affect the normal service life of the device.

    Specification:

    Table 1 Line Mode Specifications

    INVERTER MODEL

    1KVA

    2KVA

    3KVA

    3KVA Plus

    5KVA

    Input Voltage Waveform

    Sinusoidal (utility or generator)

    Nominal Input Voltage

    230Vac

    Low Loss Voltage

    170Vac±7V (UPS);
    90Vac±7V (Appliances)

    Low Loss Return Voltage

    180Vac±7V (UPS);
    100Vac±7V (Appliances)

    High Loss Voltage

    280Vac±7V

    High Loss Return Voltage

    270Vac±7V

    Max AC Input Voltage

    300Vac

    Nominal Input Frequency

    50Hz / 60Hz (Auto-detection)

    Low Loss Frequency

    40±1Hz

    Low Loss Return Frequency

    42±1Hz

    High Loss Frequency

    65±1Hz

    High Loss Return Frequency

    63±1Hz

    Output Short Circuit Protection

    Circuit Breaker

    Efficiency (Line Mode)

    >95% ( Rated R load, battery full charged )

    Transfer Time

    10ms typical (UPS); 20ms typical (Appliances)

    When AC input voltage drops to 170V, the output power will be derated.

    Table 2 Inverter Mode Specifications

    INVERTER MODEL

    1KVA

    2KVA

    3KVA

    3KVA Plus

    5KVA

    Rated Output Power

    1KVA/1KW

    2KVA/2KW

    3KVA/3KW

    5KVA/5KW

    Output Voltage Waveform

    Pure Sine Wave

    Output Voltage Regulation

    230Vac±5%

    Output Frequency

    50Hz

    Peak Efficiency

    93%

    Overload Protection

    5s@≥150% load; 10s@105%~150% load

    Surge Capacity

    2* rated power for 5 seconds

    Nominal DC Input Voltage

    12Vdc

    24Vdc

    24Vdc

    48Vdc

    Cold Start Voltage

    11.5Vdc

    23.0Vdc

    23.0Vdc

    46.0Vdc

    Low DC Warning Voltage
    @ load < 50%
    @ load ≥ 50%

    23.0Vdc
    22.0Vdc

    46.0Vdc
    44.0Vdc

    11.5Vdc
    11.0Vdc

    23.0Vdc
    22.0Vdc

    Low DC Warning Return Voltage
    @ load < 50%
    @ load ≥ 50%

    23.5Vdc
    23.0Vdc

    47.0Vdc
    46.0Vdc

    11.7Vdc
    11.5Vdc

    23.5Vdc
    23.0Vdc

    Low DC Cut-off Voltage
    @ load < 50%
    @ load ≥ 50%

    21.5Vdc
    21.0Vdc

    43.0Vdc
    42.0Vdc

    10.7Vdc
    10.5Vdc

    21.5Vdc
    21.0Vdc

    High DC Recovery Voltage

    15Vdc

    30Vdc

    32Vdc

    62Vdc

    High DC Cut-off Voltage

    16Vdc

    31Vdc

    33Vdc

    63Vdc

    No Load Power Consumption

    <25W

    <55W

    Table 3 Charge Mode Specifications


    Table 4 General Specifications

    INVERTER MODEL

    1KVA

    2KVA

    3KVA

    3KVA Plus

    5KVA

    Safety Certification

    CE

    Operating Temperature Range

    -10°C to 50°C

    Storage temperature

    -15°C~ 60°C

    Humidity

    5% to 95% Relative Humidity (Non-condensing)

    Dimension (D*W*H), mm

    88 x 225 x 320

    100 x 285 x 334

    100 x 300 x 440

    Net Weight, kg (PWM model)

    5.0

    5.5

    6.3

    N/A

    8.5

    Net Weight, kg (MPPT model)

    N/A

    N/A

    6.5

    9.5

    9.7

    Basic System Architecture

    The following illustration shows the basic application for this inverter/charger. It also includes the following devices to have a complete running system:

    • Generator or Utility.
    • PV modules

    Consult with your system integrator for other possible system architectures depending on your requirements.

    This inverter can power all kinds of appliances in-home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.


    Product Overview


    1. LCD display
    2. Status indicator
    3. Charging indicator
    4. Fault indicator
    5. Function buttons
    6. Power on/off switch
    7. AC input
    8. AC output
    9. PV input
    10. Battery input
    11. Circuit breaker
    12. USB communication port
    13. RS-232 communication port

    Operating Mode Description

    There is detailed information about as below:

    Powmr Hybrid MPPT MPPT solar charge controller Manual Download

    SPECIFICATIONS

    Table 1 Line Mode Specifications

    INVERTER MODEL

    1KVA

    2KVA

    3KVA

    3KVA Plus

    5KVA

    Input Voltage Waveform

    Sinusoidal (utility or generator)

    Nominal Input Voltage

    230Vac

    Low Loss Voltage

    170Vac±7V (UPS);
    90Vac±7V (Appliances)

    Low Loss Return Voltage

    180Vac±7V (UPS);
    100Vac±7V (Appliances)

    High Loss Voltage

    280Vac±7V

    High Loss Return Voltage

    270Vac±7V

    Max AC Input Voltage

    300Vac

    Nominal Input Frequency

    50Hz / 60Hz (Auto detection)

    Low Loss Frequency

    40±1Hz

    Low Loss Return Frequency

    42±1Hz

    High Loss Frequency

    65±1Hz

    High Loss Return Frequency

    63±1Hz

    Output Short Circuit Protection

    Circuit Breaker

    Efficiency (Line Mode)

    >95% ( Rated R load, battery full charged )

    Transfer Time

    10ms typical (UPS); 20ms typical (Appliances)

    When AC input voltage drops to 170V, the output power will be derated.

    Table 2 Inverter Mode Specifications

    INVERTER MODEL

    1KVA

    2KVA

    3KVA

    3KVA Plus

    5KVA

    Rated Output Power

    1KVA/1KW

    2KVA/2KW

    3KVA/3KW

    5KVA/5KW

    Output Voltage Waveform

    Pure Sine Wave

    Output Voltage Regulation

    230Vac±5%

    Output Frequency

    50Hz

    Peak Efficiency

    93%

    Overload Protection

    5s@≥150% load; 10s@105%~150% load

    Surge Capacity

    2* rated power for 5 seconds

    Nominal DC Input Voltage

    12Vdc

    24Vdc

    24Vdc

    48Vdc

    Cold Start Voltage

    11.5Vdc

    23.0Vdc

    23.0Vdc

    46.0Vdc

    Low DC Warning Voltage
    @ load < 50%
    @ load ≥ 50%

    23.0Vdc
    22.0Vdc

    46.0Vdc
    44.0Vdc

    11.5Vdc
    11.0Vdc

    23.0Vdc
    22.0Vdc

    Low DC Warning Return Voltage
    @ load < 50%
    @ load ≥ 50%

    23.5Vdc
    23.0Vdc

    47.0Vdc
    46.0Vdc

    11.7Vdc
    11.5Vdc

    23.5Vdc
    23.0Vdc

    Low DC Cut-off Voltage
    @ load < 50%
    @ load ≥ 50%

    21.5Vdc
    21.0Vdc

    43.0Vdc
    42.0Vdc

    10.7Vdc
    10.5Vdc

    21.5Vdc
    21.0Vdc

    High DC Recovery Voltage

    15Vdc

    30Vdc

    32Vdc

    62Vdc

    High DC Cut-off Voltage

    16Vdc

    31Vdc

    33Vdc

    63Vdc

    No Load Power Consumption

    <25W

    <55W

    Table 3 Charge Mode Specifications

    Table 4 General Specifications


    INVERTER MODEL

    1KVA

    2KVA

    3KVA

    3KVA Plus

    5KVA

    Safety Certification

    CE

    Operating Temperature Range

    -10°C to 50°C

    Storage temperature

    -15°C~ 60°C

    Humidity

    5% to 95% Relative Humidity (Non-condensing)

    Dimension (D*W*H), mm

    88 x 225 x 320

    100 x 285 x 334

    100 x 300 x 440

    Net Weight, kg (PWM model)

    5.0

    5.5

    6.3

    N/A

    8.5

    Net Weight, kg (MPPT model)

    N/A

    N/A

    6.5

    9.5

    9.7


    POW-Series (POW-Series.pdf, 2,835 Kb) [Download]

    Brand information
    Brand :
    PowMr
    Battery Information for inverters and controllers
    Lithium Battery Activation :
    • No Lithium Batteries Activation
    Battery Voltage :
    • 12V
    Battery Type :
    • Flooded Batteries
    • Gel Batteries
    • Lead-acid Batteries
    • User Mode
    Inverter Information
    Inverter Type:
    • High frequency Inverters
    Load workout with Battery:
    No
    Parallel Function:
    No
    Phase:
    • Single Phase
    Split Phase:
    No
    AC output:
    • 230Vac±5%
    Rated Load Power:
    • 1000W
    Solar Panel Information for inverters
    Max Panel Input Volt :
    • 100V-150V
    PV Terminal Charging Mode:
    • build-in MPPT Solar Charge Controller
    Max Solar Panel Input Power:
    • 500W
    Charging Current Information for inverters
    AC Charging Current:
    • 20 Amps
    PV Charging Current:
    • 40amps
    AC+PV Charging Current:
    • 60Amps
    Accessories information for inverters
    Wifi/Bluetooth Module:
    • Wifi Module(Optional)
    Find similar


    No reviews found

    You May Also Like
    • Cyber Week Deals
    • Bestsellers
    Cyber Week Deals
    Fast and high quality delivery

    Our company makes delivery all over the world

    Quality assurance and service

    We only offer quality goods with higher cost performance

    Returns within 30 days

    You have 30 days to test your purchase