EPEVER Solar Inverter Charger 5000W DC 48V AC 220V UP5000-HM8042

Write a review
Ask a question
UP5000-HM8042(RTU)
In stock
BrandEPever Lithium Battery Activation No Lithium Batteries Activation Battery Voltage48V Battery TypeLifepo4 Batteries, Lithium Batteries, Flooded Batteries, Gel Batteries, AGM Batteries, User Mode Load workout with Battery Inverter TypeHigh frequency Inverters PhaseSingle Phase AC output230Vac±5% Rated Load Power5000W Max Panel Input Volt450V-500V PV Terminal Charging Modebuild-in MPPT Solar Charge Controller Max Solar Panel Input Power4000W AC Charging Current60 Amps PV Charging Current80amps AC+PV Charging Current80Amps Wifi/Bluetooth ModuleWifi Module(Optional)
$89900
+

Minimum quantity for "EPEVER Solar Inverter Charger 5000W DC 48V AC 220V UP5000-HM8042" is 1.

Why PowMr?
  • — 24 months warranty
  • — Fast Delivery
  • — Free Shipping 
  • — Avg. response time 1 Hrs. (Working  Day)
  • PowMr Everywhere 
Wholesale

5000W solar inverter

UPower-Hi SeriesInverter/Charger

Overview
UPower-Hi series is an inverter charger that supports diversified energy management modes on solar/utility/generator charging, and utility/inverter power supply to the AC loads. To maximize solar energy utilization, users can choose energy sources according to actual needs and flexibly take the utility as a supplement. This inverter charger can raise the system's power supply guarantee rate, which is suitable for solar energy, utility/oil generator hybrid systems. It aims to provide users with high-quality, high-stability, and high-reliability electrical energy.

Features

  • Supports the battery mode or non-battery mode.
  • Non-battery mode: charging with solar (Main) and utility (Assist) simultaneously.
  • Surge and reverse connection protections to support the lithium battery system perfectly.
  • Three charging modes: Solar only, Solar priority, Utility & Solar.
  • Two AC output modes: Utility priority and Inverter priority.
  • High tracking efficiency of MPPT no less than 99.5%.
  • PFC technology achieves a high power factor of AC to DC charging and reduces grid capacity usage.
  • Advanced SPWM technology and pure sine wave output.
  • Customized charging current and discharging limited current.
  • SOC with the self-learning feature is visible on LCD.
  • 4.2 inch LCD to monitor and modify system parameters.
  • Optional WiFi or GPRS Remote control by the RS485 isolated communication port.
  • Optional BMS-Link port, which takes the charging and discharging control from BMS.

5000w solar inverter

Comprehensive electronic protection features

  1. PV protection: limit current/reverse polarity protection
  2. Night reverse charging protection
  3. Utility protection: input over voltage/ input under voltage/ input overcurrent protection
  4. Battery protection:reverse polarity/ over voltage/over discharge protection
  5. Load: output short circuit/Overload protection
  6. Inverter/charger overheating protection :The inverter/charger will stop charging/discharging when the internal temperature is too high and will resume charging/discharging when the temperature is recovered to normal.
  7. Surge and reverse connection protections to support the lithium battery system perfectly

5000W Output 220v-230v Solar Inverter Technical parameters

  • Rated battery voltage 48VDC Battery input voltage 43.2~64VDC Max. battery charging current 80A
  • General
  • Surge current 95A Zero load consumption <1.2A (without PV and utility connection, turn on the load output) Standby current <0.7A (without PV and utility connection, turn off the load output)
  • Mechanical Parameters Dimension(H x W x D) 642.5x381.6x149mm Net Weight 24kg
  • Inverter output(Output wave Pure Sine Wave)
  • Continuous output power 5000W@30℃ Max. surge power 8000W
  • Output voltage range 220VAC(-6%~+3%),230VAC(-10%~+3%) Output frequency 50/60±0.2>%
  • 80% rated output efficiency 92% Max. Rated output efficiency 91% Max. output efficiency 93%
  • Switch time 10ms(Switch from the utility output to the inverter output) 15ms(Switch from the inverter output to the utility output)

220V Solar Inverter 80A MPPT Charge Controller Specification

  • Utility charging parameter(use utility charging your battery)
  • Utility input voltage 176VAC~264VAC(Default) 90VAC~280VAC(Programmable)
  • Utility input frequency 40~65Hz Max. utility charge current 60A
  • Solar charging parameter(use solar charging your battery)
  • Max. PV open circuit voltage 500V(At minimum temperature) 440V(25℃) MPPT voltage range 120~400V
  • Max. PV input power 4000W(Note:For the curve of Max. PV input power Vs. PV open-circuit voltage, see chapter 3.4 Operating mode for details.)
  • Max. PV charging power 4000W Max. PV charging current 80A
  • Equalize charging voltage 58.4V(AGM default) Boost charging voltage 57.6V(AGM default) Float charging voltage 55.2V(AGM default) Low voltage disconnect voltage 43.2V(AGM default)
  • Tracking efficiency ≥99.5% Temp. compensate coefficient -3mV/℃/2V(Default)
  • Environment Parameters :Relative humidity < 95% (N.C.) Working temperature -20℃~50℃(When the working temperature reaches 30℃ or above, the load power is reduced appropriately; full load working is not supported)

5000w solar inverter

5000w solar inverter

5000w solar inverter

5000w solar inverter

AC OUT button&RS485 com. port&Remote temperature compensation

AC OUT button to control the AC output directly

Optional WiFi or GPRS Remote control by the RS485 isolated com. port

Remote temperature compensation for batteries.

4.2 inch LCD&LED indicators

With 4.2 inch LCD and multiple LED indicators to dynamic display the status,it is convenient to intuitively understand the working status and modifying system parameters.

Supports cold start and soft start

The instantaneous current of other inverters is large when starting, this inverter has a soft start function, which can reduce the current required for starting the inverter

BMS-Link connection port

Through a BMS-Link converter, different lithium battery manufacturers' BMS protocol can be converted into our company's standard BMS protocol. It realizes the communication between the inverter/charger and the BMS.

Epever 5kw solar inverter connection

220v epever inverter

Warm Tips:

  • When the output mode is inverter priority, and the battery voltage is lower than the low voltage disconnect voltage (configurable), the utility supplies the load.
  • The lithium battery's voltage parameters must be set according to the voltage parameters of BMS.
  • No-battery mode and battery mode can set by setting item 0.
  • AC loads shall be determined according to the output power of the inverter/charger.
  • The load exceeding the maximum output power may damage the inverter/charger.
  • When wiring the battery, please do not close the circuit breaker and ensure that the leads of "+" and "-" poles are connected correctly.
  • A circuit breaker which current is 1.25 to 2 times the rated current must be installed on the battery side away from the battery not longer than 200mm.A circuit breaker must be installed on the battery side.
  • If the inverter/charger is to be used in an area with frequent lightning strikes, installing an external surge arrester is recommended.
  • Ensure that the battery connection is correct and the battery circuit breaker is turned on first. And then, close the PV array and utility circuit breakers after the inverter/charger running normally. We won't assume any responsibility for not following the operation.
  • When supplying power for different AC loads, it is recommended to turn on the load with a large impulse current. And then turn on the load with a smaller impulse current after the load output is stable.
  • If the inverter/charger is not operating correctly or the LCD or the indicator shows an abnormality, please refer to "Troubleshooting"

NOTICE:The correct configuration of the battery capacity of the system is determined according to the specific use requirements of the load and application scenarios, otherwise it will easily lead to insufficient battery capacity or excessive waste of power generation. For details, please refer to the manual recommendation or consult us.


Specifications
Item UP3000-HM10022 UP5000-HM8042
Rated battery voltage 24VDC 48VDC
Battery input voltage 21.6~32VDC 43.2~64VDC
Max. battery charging current 100A 80A
Inverter output
Continuous output power 3000W@30℃ 5000W@30℃
Max. surge power 6000W 8000W
Output voltage range 220VAC(-6%~+3%),230VAC(-10%~+3%)
Output frequency 50/60±0.2%
Output wave Pure Sine Wave
Load power factor 0.2-1(VA ≤ continuous output power)
Distortion THD THD≤3%(Resistive load)
80% rated output efficiency 92%
Max. Rated output efficiency 91%
Max. output efficiency 93%
Switch time 10ms(Switch from the utility output to the inverter output) 15ms(Switch from the inverter output to the utility output)
Utility charging
Utility input voltage 176VAC~264VAC(Default)   90VAC~280VAC(Programmable)
Utility input frequency 40~65Hz
Max. utility charge current 80A 60A
Solar charging
Max. PV open circuit voltage 450V(At minimum temperature) 395V(25℃) 500V(At minimum temperature) 440V(25℃)
MPPT voltage range 80~350V 120~400V
Max. PV input power 4000W
(Note: For the curve of Max. PV input power Vs. PV open-circuit voltage, see chapter 3.4 Operating mode for details.)
Max. PV charging power 2875W 4000W
Max. PV charging current 100A 80A
Equalize charging voltage 29.2V(AGM default) 58.4V(AGM default)
Boost charging voltage 28.8V(AGM default) 57.6V(AGM default)
Float charging voltage 27.6V(AGM default) 55.2V(AGM default)
Low voltage disconnect voltage 21.6V(AGM default) 43.2V(AGM default)
Tracking efficiency ≥99.5%
Temp. compensate coefficient -3mV/℃/2V(Default)
General
Surge current 60A 95A
Zero load consumption <1.8A <1.2A
(without PV and utility connection, turn on the load output)
Standby current <1.2A <0.7A
(without PV and utility connection, turn off the load output)
Mechanical Parameters
Dimension(H x W x D) 642.5x381.6x149mm
Mounting size 620*300mm
Mounting hole size Φ10mm
Net Weight 19kg
Enclosure IP30
Relative humidity < 95% (N.C.)
Working temperature -20℃~50℃(When the working temperature reaches 30℃ or above, the
load power is reduced appropriately; full load working is not supported«)
Storage temperature -25℃~60℃
Altitude <5000m(If the altitude is more than 1000 meters, the rated power is reduced according to GB7260.)

Brand information
Brand :
EPever
Battery Information for inverters and controllers
Lithium Battery Activation :
  • No Lithium Batteries Activation
Battery Voltage :
  • 48V
Battery Type :
  • Lifepo4 Batteries
  • Lithium Batteries
  • Flooded Batteries
  • Gel Batteries
  • AGM Batteries
  • User Mode
Inverter Information
Inverter Type:
  • High frequency Inverters
Load workout with Battery:
Yes
Parallel Function:
No
Phase:
  • Single Phase
Split Phase:
No
AC output:
  • 230Vac±5%
Rated Load Power:
  • 5000W
Solar Panel Information for inverters
Max Panel Input Volt :
  • 450V-500V
PV Terminal Charging Mode:
  • build-in MPPT Solar Charge Controller
Max Solar Panel Input Power:
  • 4000W
Charging Current Information for inverters
AC Charging Current:
  • 60 Amps
PV Charging Current:
  • 80amps
AC+PV Charging Current:
  • 80Amps
Accessories information for inverters
Wifi/Bluetooth Module:
  • Wifi Module(Optional)
Find similar


No reviews found


You May Also Like
Fast and high quality delivery

Our company makes delivery all over the world

Quality assurance and service

We only offer quality goods with higher cost performance

Returns within 30 days

You have 30 days to test your purchase