Scharf
Verified purchase
United States
Model | POW-LVM3K-24V | POW-LVM3.5K-48V | POW-LVM5K-48V-H |
Utility/Grid | |||
Reted Input Voltage | 110/120VAC | ||
Input Voltage Range | (90Vac~140Vac) ±2% | ||
Frequency | 50Hz/60Hz(Auto detection) | ||
Frequency Range | 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz) | ||
Overload/short circuit protection | Breaker | ||
Efficiency | >95% | ||
Conversion time(bypass and inverter) | 10ms | ||
Reverse Flow Protection | Yes | ||
Max Bypass Current Overload | 40A | 40A | 63A |
Inverter | |||
Waveform | Pure Sine Wave | ||
Rated Output(VA) | 3000 | 3500 | 5000(4100/4300/4500) |
Rated Output(W) | 3000 | 3500 | 5000(4100/4300/4500) |
Power Factor | 1 | 1 | 1 |
Output AC Voltage | 120Vac | 120Vac | 120Vac(100/105/110Vac Settable) |
Unstable Input Error | ±5% | ||
Output Frequency(Hz) | 50Hz ±0.3Hz 60Hz ±0.3Hz | ||
Efficiency | >92% | >92% | >92% |
Overload Protection | (102%<load<110%)±10%:turn off the output after 5min;(110%<load<125%)±10%:turn off the output after 10sec;(125%<load)±10%: turn off the output after 5sec; | ||
Peak Power | 4500VA | 5000VA | 5000VA |
Motor Capability | 2HP | ||
Output Short Circuit Protection | Breaker | ||
Bypass Breaker Specifications | 40A | ||
Rated Battery Input Voltage | 24V (Minimum starting voltage 22V) | 48V (minimum start-up voltage 44V) | |
Battery Voltage Range | 20.0Vdc~33Vdc ± 0.6Vdc | 40.0Vdc~60Vdc ± 0.6Vdc | |
Power Saving Mode Self-consumption | ≤50W | ||
No Load Self-consumption | 48W | ||
Utility/Grid Charging | |||
Battery type | Lead acid or lithium battery | Lead acid or lithium battery | Lead Acid or Lithium |
Maximum Charging Current (AC) | 40A | 40A | 40A |
Unstable Condition Error | ± 5Adc | ± 5Adc | ± 5Adc |
Charge voltage range | 20~33Vdc | 40Vdc~60Vdc | 40 –60Vdc |
Short circuit protection | Circuit breaker and blown fuse | Breakers and fuses | Breakers and blown fuses |
Circuit breaker specifications | Yes | 40A | 63A |
Overcharge protection | Yes; Automatically alerts and then turns off charging after1 minute | Yes; Automatically alerts and then turns off charging after1 minute | Yes; Automatically alerts and then turns off charging after1 minute |
Solar (PV) charging | |||
Recommended PV Max | 100Vdc | 145Vdc (150 VDC Actual) | 500Vdc |
PV Operating Voltage | 30-100Vdc | 60-145VDC | 120-500Vdc |
MPPT Voltage Range | 30-95Vdc | 60-115VDC | 120-450Vdc |
Battery Charging Range | 20-33Vdc | 40-60VDC | 40-60Vdc |
Maximum Input Power | 1400W | 4400W | 5000W |
Maximum Input Current | 60A | 80A | 80A |
Maximum Output Power | 1400W | 4200W | 5000W |
PV Charging Current Range | 0-60A | 0-80A | 0-80A |
Short-circuit Protection | Blown fuse | Internal Fuse | Internal Fuse |
Wiring Protection | Reverse Polarity | Reverse polarity | Reverse Polarity |
General | |||
Certification | FCC Part 15 Class B, RoHS | FCC Part 15 Class B, RoHS | CE(IEC62109), RoHS, EN61000 |
Operating Temperature | 5°F ~ 131°F/ -15°C ~ 55°C | 5°F ~ 131°F/ -15°C ~ 55°C | 5°F ~ 131°F/ -15°C ~ 55°C |
Storage Temperature | -13°F ~ 140°F / -25°C ~ 60°C | -13°F ~ 140°F / -25°C ~ 60°C | -13°F ~ 140°F / -25°C ~ 60°C |
Humidity range | 5% to 95% (Conformal coating protection) | 5% to 95% (three-layer paint protection) | 5% to 95% (three-layer paint protection) |
Noise | ≤60dB | ≤60dB | ≤60dB |
Cooling | Fans | Fans | Fans, Forced cooling with adjustable air speed |
IP Grade | IP 20 | IP 20 | IP 20 |
Safety | Class I | Class I | I |
Dimensions (L-W-D) | 14.8*11*4.05 in / 378mm*280mm*103mm | 16.8*12.7*4.9 in / 426*322*124 mm | 16.8*12.7*4.9 in / 426*322*124 mm |
Weight (kg) | 14.96 lbs /6.8kg | 23.8 lbs /10.8kg | 25.6 lbs /11.6kg |
Non-Lithium Battery Parameters
Battery type | Sealed lead acid battery (SLD) | Colloidal lead acid battery (GEL) | Vented lead acid battery (FLD) | User-defined (USE) |
Parameters | ||||
Overvoltage disconnection voltage | 60V | 60V | 60V | 60V |
Equalizing charge voltage | 58.4V | 56.8V | 59.2V | 40~60V |
(adjustable) | ||||
Boost charge voltage | 57.6V | 56.8V | 58.4V | 40~60V |
(adjustable) | ||||
Floating charge voltage | 55.2V | 55.2V | 55.2V | 40~60V |
(adjustable) | ||||
Undervoltage alarm voltage | 44V | 44V | 44V | 40~60V |
(adjustable) | ||||
Low voltage | 42V | 42V | 42V | 40~60V |
disconnection voltage | (adjustable) | |||
Discharge limit voltage | 40V | 40V | 40V | 40~60V |
(adjustable) | ||||
Over-discharge delay time | 5S | 5S | 5S | 1~30S |
(adjustable) | ||||
Equalizing charge duration | 120 minutes | - | 120 minutes | 0~600 minutes |
(adjustable) | ||||
Equalizing charge interval | 30 days | - | 30 days | 0~250 days |
(adjustable) | ||||
Boost charge duration | 120 minutes | 120 minutes | 120 minutes | 10~600 minutes |
(adjustable) |
Question: | Can i use a Step down converter on my batteries to attach a 5th 12volt battery for my RV's 12 volt system? |
Answer: | This inverter can only be connected to 48V batteries, if you connect 4 12V batteries in series to form 48V, this must be no problem. It is not feasible to use a step down converter, it will not be able to withstand the output current and will be damaged. |
Question: | Does this operate at 5000 watts automatically or will it use wattage as needed? |
Answer: | It can only connect a maximum load of 5KW, and a maximum of 5.5KW solar panels. As for the output power, it depends on the load you connect. Assuming you only connect a 500W load, the inverter will only output around 600W. If it outputs 5000W of power, your 500W load will be damaged long ago. |
Question: | Can i wire a 30 amp outlet onto this? |
Answer: | I can not understand your mean, what's 30 amp outlet? |
Question: | Where/how do you wire the ground for the AC out? |
Answer: | Please check User manual Page 14, there is Ground wiring Icon |
Question: | Where/how do you wire the ground for the AC out? |
Answer: | Please check User manual Page 14, there is Ground wiring Icon |
Question: | can i use 2 of this inverter to make split phase 110v / 220v |
Answer: | NO |
Question: | Compatible with Lifepo4 battery bank? |
Answer: | yes. It is ok |
Question: | Can two 5k inverters be connected parallel to achieve 10k on both input and output? |
Answer: | NO. This inverter doesn't support two or more parallel |
Question: | is there a plan for a firm upgrade for multiple units to be run in parallel? and/ or have units operate in 120/240 V mode (US) split-phase? |
Answer: | NO. this inverter can't run in parallel |
Question: | Other versions of the 5kw show connected to generator in the ads will this one connect to an ac generator through the ac input? |
Answer: | YES. |
Question: | My volts on the multimeter read 103 volts coming from the solar panels(3 x 38 connected in series) will this work to charge? |
Answer: | YES. it is ok to charge your battery. |
Question: | Can this be used as a grid tie inverter to feed electricity back into the grid? |
Answer: | NO. This can't be used as a grid tie inverter |
Question: | what does the wifi module do? does it log data? can you adjust the settings? Is there any info on the software or app needed to interface? |
Answer: | Yes the wifi module can set up some data, there has an APP to download it. |
Question: | can i use a step up converter to convert a 12v battery to 48v for use with this hybrid inverter? |
Answer: | You can not do this. The battery is a stable power supply and cannot be converted into a 48V voltage by the converter, it can only be achieved 4 12v batteries in series. |
Question: | Can i use 12v solar panels with this? Can i use 48v solar panels with this? |
Answer: | The max PV input voltage is 500VDC. Just don't exceed this range. |
Our company makes delivery all over the world
We only offer quality goods with higher cost performance
You have 30 days to test your purchase