PowMr Solar Inverter Charger 3KW 120V AC MPPT 60A Solar Charge Controller PV 100V lifepo4 Battery And Lead Acid Battery

Write a review
Ask a question
POW-LVM3K-24V
In stock
5% OFF Solar Inverter Charger
BrandPowMr Lithium Battery Activation Active Lithium Batteries Battery Voltage24V Battery TypeLifepo4 Batteries, Lithium Batteries, Flooded Batteries, Gel Batteries, Lead-acid Batteries, AGM Batteries PhaseSingle Phase Inverter TypeHigh frequency Inverters AC output120Vac±5% Rated Load Power3000W Max Panel Input Volt100V-150V PV Terminal Charging Modebuild-in MPPT Solar Charge Controller Max Solar Panel Input Power1400W AC Charging Current40 Amps PV Charging Current60amps AC+PV Charging Current60Amps Wifi/Bluetooth ModuleWifi Module(Optional) WarehouseUSA Warehouse
$59900
$56905
You save: $2995
+

Minimum quantity for "PowMr Solar Inverter Charger 3KW 120V AC MPPT 60A Solar Charge Controller PV 100V lifepo4 Battery And Lead Acid Battery" is 1.

Why PowMr?
  • — 24 months warranty
  • — Fast Delivery
  • — 8 hours service 
  • PowMr Everywhere 

Wholesale

PowMr Solar Inverter Charger 3KW 120V AC MPPT 60A Solar Charge Controller PV 100V Lithium Battery And Lead Acid Battery

Pow series is a new hybrid solar charge inverter, which integrates solar energy storage & means charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard. Four charging modes are optional.Based on full-digital intelligent design, the DC-AC inverter module employs advanced SPWM technology and outputs pure sine wave to convert DC into AC. It is ideal for AC loads such as household appliances, power tools, industrial equipment, and electronic audio and video equipment.

Feature

  • Brand: PowMr
  • Product Model: POW-LVM3K-24V
  • Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sine wave
  • Two output modes: mains bypass and inverter output; uninterrupted power supply
  • Available in 4 charging modes: Only Solar, Utility Priority, PV Priority, Utility & Solar hybrid charging
  • Advanced MPPT technology with an efficiency of 99.9%
  • Designed with a LCD screen and 3 LED indicators for dynamic display of system data and operating status
  • Manual ON/OFF switch controlling AC output
  • Power saving mode available to reduce empty load loss
  • Intelligent variable speed fan to efficiently dissipate heat and extend system life
  • Lithium battery activation by PV solar or mains, allowing access of lead-acid battery and lithium battery
  • Complete protections, including short circuit protection, over voltage and under voltage protection, overload protection, reverse protection, etc

Product Overview

  1. LCD Buttons
  2. Mounting Holes
  3. LCD Screen
  4. LED Indicators
  5. AC Input Breaker
  6. Dry Contact Port
  7. RS485 Communication Port
  8. USB Debugging Port (Internal Use)
  9. AC Input Terminal
  10. AC Output Terminal
  11. Cooling Fans
  12. PV Input Terminal
  13. Main On/Off Power Switch
  14. Battery Input Terminal
  15. Grounding Lug

Dimensions

Installation

Please read this manual carefully and familiarize yourself with the installation procedures before installation.

Installation Safety

The unit should be installed in a well-ventilated, cool, and dry environment. Make sure the fans of the unit and the ventilation holes are not blocked.

Do not expose the unit to rain, moisture, snow, or liquids of any type.

Never install the inverter in a sealed enclosure with flooded batteries. Gas can accumulate and there is a risk of explosion.

Do not install the inverter in the same compartment as the battery bank because it could serve as a potential fire hazard.

Location Recommendations

Ensure installation follows the following guidelines:

  1. Cool, dry, well-ventilated area — Heat is the worst enemy for electronic equipment.Inverters must be in an area where the fans are not blocked or where they are not exposed directly to the sun. They should be in an area free of any kind of moisture and allow for clearance of at least 8” around the unit to provide adequate ventilation.
  2. Protection against fire hazard — the unit should be away from any flammable material, liquids, or any other combustible material. The unit can spark and the consequences could be severe.
  3. Close proximity to battery bank—prevent excessive voltage drop by keeping the unit close to the battery bank and having a properly sized wire going from the battery bank to the inverter.
  4. Limiting electromagnetic interference (EMI) — ensure the inverter is firmly grounded to a building, vehicle, or earth grounded. Keep the inverter away from EMI receptors such as TVs, radios, and other audio/visual electronics to prevent damage/interference to the equipment.

Other Precautions:

  • When installing the battery, be very careful, when installing lead-acid liquid batteries, you should wear protective glasses, once in contact with battery acid, please wash with water in time.
  • Avoid placing metal objects near the battery to prevent short circuits in the battery.
  • Acid gas may be generated when the battery is charged so ensure good ventilation around the environment.
  • Incorrect or improper connection points and corroded wires can cause great heat to melt the wire insulation, burning surrounding materials, and even cause fire, so ensure that the connection is tightened
  • It is best to avoid mobile applications when the wire shakes and cause the connection head loose. Outdoor installation should avoid direct sunlight and rain, snow.
  • Do not install the solar inverter in harsh environments such as damp, greasy, flammable and explosive areas or where dust accumulation is high.
  • The municipal electrical input and AC output are high voltage, do not touch the wiring. Do not touch the unit when the fan is working.
  • To avoid damage, do not use more than one (in parallel) input AC power supply.

Please Note: While the Solar inverter has fans for cooling, this installation location optimal for natural convection cooling will improve the overall efficiency

Technical Specifications

Model

POW-LVM3K-24V

Utility/Grid

Rated input Voltage

110/120Vac

Input voltage range

(90Vac~140Vac) ±2%

Frequency

50Hz/ 60Hz (auto detect)

Frequency range

47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~65±0.3Hz (60Hz);

Overload / Short circuit Protection

Breaker

Efficiency

>95%

Conversion time (Bypass and reverse)

10ms

Reverse Flow Protection

Yes

Max Bypass Current load

40A

Inverter

Waveform

Pure Sine Wave

Rated Output (VA)

3000

Rated Output (W)

3000

Power factor

1

Output AC Voltage

120Vac

Unstable Input Error

±5%

Output Frequency (Hz)

50Hz ±0.3Hz 60Hz ± 0.3Hz

Efficiency

>92%

 

 

Overload protection

For U model:

(102% < load <110%) ±10%: report error and turn off
the output after 5 minutes; (110% < load < 125%) ±
10%: report error and turn off the output after 10 seconds;

Load >125% ±10%: report error and turn off the output after 5 seconds;

Peak power

4500VA

Motor Capability

2HP

Output Short-circuit Protection

Breaker

Bypass Breaker Specifications

40A

Rated Battery Voltage

24V (Minimum starting voltage 22V)

Battery voltage range

20.0Vdc~33Vdc ± 0.6Vdc

Power Saving Mode Self-Consumption

≤50W

No Load Self Consumption

48W

Model

POW-LVM3K-24V

Utility/Grid Charging

Battery type

Lead Acid or Lithium Battery

Maximum Charging Current (AC)

40A

Unstable Condition Error

± 5Adc

Charging Voltage Range

20 – 33Vdc

Short-circuit protection

Circuit breaker and blown fuse

Circuit Breaker Specifications

40A

 

Overcharge Protection

Yes; Automatically alerts and then turns off charging after1 minute

Solar (PV) Charging

Recommended PV Max

100Vdc

PV Operating Voltage

30-100Vdc

MPPT Voltage Range

30-95Vdc

Battery Charging Range

20-33Vdc

Maximum Input Power

1400W

Maximum Input Current

60A

Maximum Output Power

1400W

PV Charging Current Range

0-60A

Short-circuit Protection

Blown fuse

Wiring Protection

Reverse Polarity

General

Certifications

FCC Part 15 Class B, RoHS

Operating Temperature

5°F ~ 131°F/ -15°C ~ 55°C

Storage Temperature

-13°F ~ 140°F / -25°C ~ 60°C

Humidity

5% to 95% (three-layer paint protection)

Noise

≤60dB

Cooling

Fans

IP Grade

IP 20

Safety Class

I

Dimensions (L-W-D)

14.8*11*4.05 in / 378mm*280mm*103mm

Weight

14.96 lbs /6.8kg

Non-Lithium Battery Parameters

Battery type

Parameters

Sealed lead acid battery (SLD)

Colloidal lead acid battery (GEL)

Vented lead acid battery (FLD)

User-defined (User)

Overvoltage
disconnection voltage

30.0V

30.0V

30.0V

18~30V

Equalizing charge voltage

29.2V

-

29.6V

18~30V

Boost charge voltage

28.8V

28.4V

29.2V

18~30V
(adjustable)

Floating charge voltage

27.6V

27.6V

27.6V

18~30V
(adjustable)

Undervoltage alarm voltage

22.0V

22.0V

22.0V

18~30V
(adjustable)

Low voltage disconnection
voltage

21.0V

21.0V

21.0V

18~30V
(adjustable)

Discharge limit voltage

20.0V

20.0V

20.0V

18~30V
(adjustable)

Over-discharge delay time

5S

5S

5S

1~30S
(adjustable)

Equalizing charge duration

120 minutes

-

120 minutes

0~600 minutes
(adjustable)

Equalizing charge interval

30 days

-

30 days

0~250 days
(adjustable)

Boost charge duration

120 minutes

120 minutes

120 minutes

10~600 minutes
(adjustable)

When modifying parameters in User Mode, the following rules must be followed to set parameters successfully.

  1. Overvoltage Disconnect > Overvoltage Disconnect Recover ≥ Equalization voltage
    ≥ Boost voltage ≥ Float voltage
  2. Overvoltage Disconnect > Over Voltage Disconnect Recover
  3. Low Voltage Disconnect Recover > Low Voltage Disconnect (at least 2V Smaller)< Discharge Limit Voltage
  4. Undervoltage Recover > Undervoltage Alarm

Lithium Battery Parameters

Battery type

Parameters

Ternary
lithium battery (N07)

Ternary
lithium battery (N08)

Lithium iron
phosphat e battery (LF07)

Lithium iron
phosphat e battery (LF08)

Lithium iron
phosphate battery (LF09)

User defined (User)

Overvoltage disconnection
voltage

 

31.6V

 

33V

 

30V

 

30V

 

31.6V

 

18~30V

Equalizing charge voltage

28.8V (adjustable)

31.6V (adjustable)

24.6V (adjustable)

28.4V (adjustable)

31.6V (adjustable)

18~30V

 

Boost charge voltage

28.8V (adjustable)

31.6V (adjustable)

24.6V (adjustable)

28.4V (adjustable)

31.6V (adjustable)

18~30V (adjustable)

Floating charge voltage

28.8V (adjustable)

31.6V (adjustable)

24.6V (adjustable)

28.4V (adjustable)

31.6V (adjustable)

18~30V (adjustable)

Undervoltage alarm voltage

23.4V (adjustable)

26.8V (adjustable)

21.6V (adjustable)

24.8V (adjustable)

27.8V (adjustable)

18~30V (adjustable)

Low voltage disconnection
voltage

21.0V (adjustable)

24.0V (adjustable)

21.0V (adjustable)

24.4V (adjustable)

27.0V (adjustable)

18~30V (adjustable)

Discharge limit voltage

 

19.6V

 

22.4V

 

20.4V

 

23.2V

 

26.2V

18~30V (adjustable)

Over-discharge delay time

30s
(adjustable)

30s
(adjustable)

30s
(adjustable)

30s
(adjustable)

30s
(adjustable)

1~30s
(adjustable)

Equalizing charge duration

 

-

 

-

 

-

 

-

 

-

0~600minutes
(adjustable)

Equalizing charge interval

 

-

 

-

 

-

 

-

 

-

0~250days
(adjustable)

Boost charge duration

120 minutes (adjustable)

120 minutes (adjustable)

120 minutes (adjustable)

120 minutes (adjustable)

120 minutes (adjustable)

10~600
Minutes
(adjustable)

When modifying parameters in User Mode or Lithium, the following rules must be followed to set parameters successfully.

  1. Overvoltage Disconnect > Overvoltage Disconnect Recover ≥ Equalization voltage ≥Boost voltage ≥ Float voltage
  2. Overvoltage Disconnect > Over Voltage Disconnect Recover
  3. Low Voltage Disconnect Recover > Low Voltage Disconnect (at least 2V Smaller) < Discharge Limit Voltage
  4. Undervoltage Recover > Undervoltage Alarm

User Manual (POW-LVM3K-24V.pdf, 1,517 Kb) [Download]

Wifi Model Manual (HF-Wi-Fi_-Module.pdf, 2,267 Kb) [Download]

Brand information
Brand :
PowMr
Battery Information for inverters and controllers
Lithium Battery Activation :
  • Active Lithium Batteries
Battery Voltage :
  • 24V
Battery Type :
  • Lifepo4 Batteries
  • Lithium Batteries
  • Flooded Batteries
  • Gel Batteries
  • Lead-acid Batteries
  • AGM Batteries
Inverter Information
Inverter Type:
  • High frequency Inverters
Load workout with Battery:
No
Parallel Function:
No
Phase:
  • Single Phase
Split Phase:
No
AC output:
  • 120Vac±5%
Rated Load Power:
  • 3000W
Solar Panel Information for inverters
Max Panel Input Volt :
  • 100V-150V
PV Terminal Charging Mode:
  • build-in MPPT Solar Charge Controller
Max Solar Panel Input Power:
  • 1400W
Charging Current Information for inverters
AC Charging Current:
  • 40 Amps
PV Charging Current:
  • 60amps
AC+PV Charging Current:
  • 60Amps
Accessories information for inverters
Wifi/Bluetooth Module:
  • Wifi Module(Optional)
Other Information
Warehouse:
  • USA Warehouse
Find similar


4.7 out of 5
Reviews: 15
5 stars
73%
4 stars
27%
3 stars
0%
2 stars
0%
1 star
0%
Customer
Verified purchase
United States
Comment
Wonderful product!
John
Verified purchase
United States
Advantages
Powerful all in one unit for Van Conversion
Comment
Just received the unit and haven’t used it yet. Feels sturdy and well assembled. I will be installing it in a van conversion soon and will update after I get it live.I will have 700watts of solar on van roof and 277ah lifpo4 battery.Update:It's all installed and running fine.In the off-grid mode, I loaded up to 2000watts (lights/fan/electric water heater) and it had no issue. The cooling fans will kick on at that load level which do contribute a bit of noise.It is important to follow the clearances for installation for cooling, especially if the unit is mounted in a warmer location and/or will be loaded up heavily with electric loads.The next day when the sun comes up it recharges the bank from the solar.I have my van shore power connection wired directly to this unit. When I'm plugged into shore power it tops off the batteries if needed and provides any AC and DC power needed for loads.These settings are all adjustable which is great.
daren
Verified purchase
United States
Advantages
Easy to hook up and install
Comment
Works as it should so far havent hooked in solar yet. But grid tie and batteries work. Currently have it on a 15amp cord so when I'm working in the trailer and my demand is higher than that it automatically transfers to the inverter and batteries and keeps me going I am thus far very pleased with the system.Only thing that would be nice is if programing was more user friendly or intuitive.
allan
Verified purchase
United States
Advantages
Just got this running
Comment
Just got this running in a class A RV couples with 206AH battery and 3 200W panels. Very pleased with unit, operation and price. My only complaint is the inverter runs off the battery while the panels charge the battery which causes slight discharge/charge cycles of the battery. I have not yet contacted supplier for advice, I may update this review once I have.
Nicholas S.
Verified purchase
United States
Advantages
Does what it’s supposed to as expected
Comment
So far it works as expected maybe even better. Currently using as battery back up and soon will have running completely on solar with the hopes of reducing my utility dependency. Easy install, great size to Mount in discrete locations.
Max J.
Verified purchase
United States
Advantages
Great product
Comment
I install it myself and it worth the effort. It's working pretty well right now.
James
Verified purchase
United States
Advantages
So Far So Good
Comment
I'm in the Sunshine State with hurricane season approaching. I have several gasoline generators but at 5 gallons every 8 hours I wanted to convert to solar. I needed to power not only small household appliances such as fans, TV, small refrigerator etc, but also 5000 BTU A/C, 9 cu ft deep freeze, chop saw, 1.5 hp air compressor and other larger tools. I was originally looking for a 24v, 3500 watt pure sine wave inverter but decided to take a chance on the HF 2430U60-100. The combined charge controller and inverter really appealed to me, one less headache for about the same price.I have eight 100w panels at 80 volts open circuit with direct overhead sunshine for about 8 hours a day feeding a 24 volt battery bank of four 12V AGM 100aH. So far, this device has handled it all with ease. No buzz in the appliances, no hesitation with the larger tools. I have run the chop saw at the same time as the deep freeze, fridge, ceiling fan and TV. I've had it for about 4 weeks and finally getting it dialed in. Set-up was fairly easy and straight forward. I'm no expert and consider myself moderately capable, but you'll definitely need the User Manual for parameter setup and it is somewhat confusing. I ran straight solar for a while to test everything but have since switched to hybrid mode which is pretty sweet. I'll probably add two more batteries to run solar 24/7. In the meantime I'll manage the load as necessary. Pleasantly Surprised. Might be worth a try.
Plumbing Solutions
Verified purchase
United States
Advantages
Easy to hook up
Comment
Works great, easy set up. Only flaw is they don't support hooking up more in series for more power. I run all the lights and ceiling fans of this one with no issues.
Brian
Verified purchase
United States
Advantages
Excellent solution for running off of multiple power supplies
Comment
Love it! You can configure it how you want, it was pretty easy to install (for those who are capable). Seams to be of good quality and I love the way it works.
Rick R.
Verified purchase
United States
Advantages
Por el precio es lo que se debe esperar
Comment
Es lo se debe de esperar por el precio - +/-$500 USD. Solo ha estado en servicio para unos días. Hace lo que debe de hacer. No es de una calidad de la primera. Es una buena opción para economizar y experimentar en un sistema solar sin hacer una inversion grande.

You May Also Like
  • Bestsellers
  • Most Popular
Bestsellers
Fast and high quality delivery

Our company makes delivery all over the world

Quality assurance and service

We only offer quality goods with higher cost performance

Returns within 30 days

You have 30 days to test your purchase