PowMr Solar Inverter Charger 3KW 120V AC MPPT 60A Solar Charge Controller PV 100V Lithium Battery And Lead Acid Battery

POW-LVM3K-24V
$45999
$41799
You save: $42.00
In stock
Shipping Item(s) From China Warehouse If Out Of Stock In Location Warehouse
Ship to Worldwide from Shenzhen China Only Ship to USA from United States Only Ship to Australia from Australia Ship to Germany and European from Germany Ship to European Countries and UK from United Kindom
Price in points: 418 points
+

Minimum quantity for "PowMr Solar Inverter Charger 3KW 120V AC MPPT 60A Solar Charge Controller PV 100V Lithium Battery And Lead Acid Battery" is 1.

Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price

PowMr UK warehouse,AUS warehouse,USA warehouse,GER warehouse and China warehouse

PowMr Solar Inverter Charger 3KW 120V AC MPPT 60A Solar Charge Controller PV 100V Lithium Battery And Lead Acid Battery

Pow series is a new hybrid solar charge inverter, which integrates solar energy storage & means charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard. Four charging modes are optional.Based on full-digital intelligent design, the DC-AC inverter module employs advanced SPWM technology and outputs pure sine wave to convert DC into AC. It is ideal for AC loads such as household appliances, power tools, industrial equipment, and electronic audio and video equipment.

Feature

  • Brand: PowMr
  • Product Model: POW-LVM3K-24V
  • Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sine wave
  • Two output modes: mains bypass and inverter output; uninterrupted power supply
  • Available in 4 charging modes: Only Solar, Utility Priority, PV Priority, Utility & Solar hybrid charging
  • Advanced MPPT technology with an efficiency of 99.9%
  • Designed with a LCD screen and 3 LED indicators for dynamic display of system data and operating status
  • Manual ON/OFF switch controlling AC output
  • Power saving mode available to reduce empty load loss
  • Intelligent variable speed fan to efficiently dissipate heat and extend system life
  • Lithium battery activation by PV solar or mains, allowing access of lead-acid battery and lithium battery
  • Complete protections, including short circuit protection, over voltage and under voltage protection, overload protection, reverse protection, etc

Product Overview

  1. LCD Buttons
  2. Mounting Holes
  3. LCD Screen
  4. LED Indicators
  5. AC Input Breaker
  6. Dry Contact Port
  7. RS485 Communication Port
  8. USB Debugging Port (Internal Use)
  9. AC Input Terminal
  10. AC Output Terminal
  11. Cooling Fans
  12. PV Input Terminal
  13. Main On/Off Power Switch
  14. Battery Input Terminal
  15. Grounding Lug

Dimensions

Installation

Please read this manual carefully and familiarize yourself with the installation procedures before installation.

Installation Safety

The unit should be installed in a well-ventilated, cool, and dry environment. Make sure the fans of the unit and the ventilation holes are not blocked.

Do not expose the unit to rain, moisture, snow, or liquids of any type.

Never install the inverter in a sealed enclosure with flooded batteries. Gas can accumulate and there is a risk of explosion.

Do not install the inverter in the same compartment as the battery bank because it could serve as a potential fire hazard.

Location Recommendations

Ensure installation follows the following guidelines:

  1. Cool, dry, well-ventilated area — Heat is the worst enemy for electronic equipment.Inverters must be in an area where the fans are not blocked or where they are not exposed directly to the sun. They should be in an area free of any kind of moisture and allow for clearance of at least 8” around the unit to provide adequate ventilation.
  2. Protection against fire hazard — the unit should be away from any flammable material, liquids, or any other combustible material. The unit can spark and the consequences could be severe.
  3. Close proximity to battery bank—prevent excessive voltage drop by keeping the unit close to the battery bank and having a properly sized wire going from the battery bank to the inverter.
  4. Limiting electromagnetic interference (EMI) — ensure the inverter is firmly grounded to a building, vehicle, or earth grounded. Keep the inverter away from EMI receptors such as TVs, radios, and other audio/visual electronics to prevent damage/interference to the equipment.

Other Precautions:

  • When installing the battery, be very careful, when installing lead-acid liquid batteries, you should wear protective glasses, once in contact with battery acid, please wash with water in time.
  • Avoid placing metal objects near the battery to prevent short circuits in the battery.
  • Acid gas may be generated when the battery is charged so ensure good ventilation around the environment.
  • Incorrect or improper connection points and corroded wires can cause great heat to melt the wire insulation, burning surrounding materials, and even cause fire, so ensure that the connection is tightened
  • It is best to avoid mobile applications when the wire shakes and cause the connection head loose. Outdoor installation should avoid direct sunlight and rain, snow.
  • Do not install the solar inverter in harsh environments such as damp, greasy, flammable and explosive areas or where dust accumulation is high.
  • The municipal electrical input and AC output are high voltage, do not touch the wiring. Do not touch the unit when the fan is working.
  • To avoid damage, do not use more than one (in parallel) input AC power supply.

Please Note: While the Solar inverter has fans for cooling, this installation location optimal for natural convection cooling will improve the overall efficiency

Technical Specifications

Model

POW-LVM3K-24V

Utility/Grid

Rated input Voltage

110/120Vac

Input voltage range

(90Vac~140Vac) ±2%

Frequency

50Hz/ 60Hz (auto detect)

Frequency range

47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~65±0.3Hz (60Hz);

Overload / Short circuit Protection

Breaker

Efficiency

>95%

Conversion time (Bypass and reverse)

10ms

Reverse Flow Protection

Yes

Max Bypass Current load

40A

Inverter

Waveform

Pure Sine Wave

Rated Output (VA)

3000

Rated Output (W)

3000

Power factor

1

Output AC Voltage

120Vac

Unstable Input Error

±5%

Output Frequency (Hz)

50Hz ±0.3Hz 60Hz ± 0.3Hz

Efficiency

>92%

 

 

Overload protection

For U model:

(102% < load <110%) ±10%: report error and turn off
the output after 5 minutes; (110% < load < 125%) ±
10%: report error and turn off the output after 10 seconds;

Load >125% ±10%: report error and turn off the output after 5 seconds;

Peak power

4500VA

Motor Capability

2HP

Output Short-circuit Protection

Breaker

Bypass Breaker Specifications

40A

Rated Battery Voltage

24V (Minimum starting voltage 22V)

Battery voltage range

20.0Vdc~33Vdc ± 0.6Vdc

Power Saving Mode Self-Consumption

≤50W

No Load Self Consumption

48W

Model

POW-LVM3K-24V

Utility/Grid Charging

Battery type

Lead Acid or Lithium Battery

Maximum Charging Current (AC)

40A

Unstable Condition Error

± 5Adc

Charging Voltage Range

20 – 33Vdc

Short-circuit protection

Circuit breaker and blown fuse

Circuit Breaker Specifications

40A

 

Overcharge Protection

Yes; Automatically alerts and then turns off charging after1 minute

Solar (PV) Charging

Recommended PV Max

100Vdc

PV Operating Voltage

30-100Vdc

MPPT Voltage Range

30-95Vdc

Battery Charging Range

20-33Vdc

Maximum Input Power

1400W

Maximum Input Current

60A

Maximum Output Power

1400W

PV Charging Current Range

0-60A

Short-circuit Protection

Blown fuse

Wiring Protection

Reverse Polarity

General

Certifications

FCC Part 15 Class B, RoHS

Operating Temperature

5°F ~ 131°F/ -15°C ~ 55°C

Storage Temperature

-13°F ~ 140°F / -25°C ~ 60°C

Humidity

5% to 95% (three-layer paint protection)

Noise

≤60dB

Cooling

Fans

IP Grade

IP 20

Safety Class

I

Dimensions (L-W-D)

14.8*11*4.05 in / 378mm*280mm*103mm

Weight

14.96 lbs /6.8kg

Non-Lithium Battery Parameters

Battery type

Parameters

Sealed lead acid battery (SLD)

Colloidal lead acid battery (GEL)

Vented lead acid battery (FLD)

User-defined (User)

Overvoltage
disconnection voltage

30.0V

30.0V

30.0V

18~30V

Equalizing charge voltage

29.2V

-

29.6V

18~30V

Boost charge voltage

28.8V

28.4V

29.2V

18~30V
(adjustable)

Floating charge voltage

27.6V

27.6V

27.6V

18~30V
(adjustable)

Undervoltage alarm voltage

22.0V

22.0V

22.0V

18~30V
(adjustable)

Low voltage disconnection
voltage

21.0V

21.0V

21.0V

18~30V
(adjustable)

Discharge limit voltage

20.0V

20.0V

20.0V

18~30V
(adjustable)

Over-discharge delay time

5S

5S

5S

1~30S
(adjustable)

Equalizing charge duration

120 minutes

-

120 minutes

0~600 minutes
(adjustable)

Equalizing charge interval

30 days

-

30 days

0~250 days
(adjustable)

Boost charge duration

120 minutes

120 minutes

120 minutes

10~600 minutes
(adjustable)

When modifying parameters in User Mode, the following rules must be followed to set parameters successfully.

  1. Overvoltage Disconnect > Overvoltage Disconnect Recover ≥ Equalization voltage
    ≥ Boost voltage ≥ Float voltage
  2. Overvoltage Disconnect > Over Voltage Disconnect Recover
  3. Low Voltage Disconnect Recover > Low Voltage Disconnect (at least 2V Smaller)< Discharge Limit Voltage
  4. Undervoltage Recover > Undervoltage Alarm

Lithium Battery Parameters

Battery type

Parameters

Ternary
lithium battery (N07)

Ternary
lithium battery (N08)

Lithium iron
phosphat e battery (LF07)

Lithium iron
phosphat e battery (LF08)

Lithium iron
phosphate battery (LF09)

User defined (User)

Overvoltage disconnection
voltage

 

31.6V

 

33V

 

30V

 

30V

 

31.6V

 

18~30V

Equalizing charge voltage

28.8V (adjustable)

31.6V (adjustable)

24.6V (adjustable)

28.4V (adjustable)

31.6V (adjustable)

18~30V

 

Boost charge voltage

28.8V (adjustable)

31.6V (adjustable)

24.6V (adjustable)

28.4V (adjustable)

31.6V (adjustable)

18~30V (adjustable)

Floating charge voltage

28.8V (adjustable)

31.6V (adjustable)

24.6V (adjustable)

28.4V (adjustable)

31.6V (adjustable)

18~30V (adjustable)

Undervoltage alarm voltage

23.4V (adjustable)

26.8V (adjustable)

21.6V (adjustable)

24.8V (adjustable)

27.8V (adjustable)

18~30V (adjustable)

Low voltage disconnection
voltage

21.0V (adjustable)

24.0V (adjustable)

21.0V (adjustable)

24.4V (adjustable)

27.0V (adjustable)

18~30V (adjustable)

Discharge limit voltage

 

19.6V

 

22.4V

 

20.4V

 

23.2V

 

26.2V

18~30V (adjustable)

Over-discharge delay time

30s
(adjustable)

30s
(adjustable)

30s
(adjustable)

30s
(adjustable)

30s
(adjustable)

1~30s
(adjustable)

Equalizing charge duration

 

-

 

-

 

-

 

-

 

-

0~600minutes
(adjustable)

Equalizing charge interval

 

-

 

-

 

-

 

-

 

-

0~250days
(adjustable)

Boost charge duration

120 minutes (adjustable)

120 minutes (adjustable)

120 minutes (adjustable)

120 minutes (adjustable)

120 minutes (adjustable)

10~600
Minutes
(adjustable)

When modifying parameters in User Mode or Lithium, the following rules must be followed to set parameters successfully.

  1. Overvoltage Disconnect > Overvoltage Disconnect Recover ≥ Equalization voltage ≥Boost voltage ≥ Float voltage
  2. Overvoltage Disconnect > Over Voltage Disconnect Recover
  3. Low Voltage Disconnect Recover > Low Voltage Disconnect (at least 2V Smaller) < Discharge Limit Voltage
  4. Undervoltage Recover > Undervoltage Alarm

Correct Connecting Order : Battery - solar panel - load

Disconnect : solar panel - battery - load


User Manual (POW-LVM3K-24V.pdf, 1,517 Kb) [Download]