Powmr 7200W 230V AC System 48V DC Solar Inverter Charger Built-In 80A MPPT Solar Charge Controller Max PV 500V Off-Grid Inverter With Parallel 6 Units 2 MPP Tracker

POW-MAX-7.2KW-48V-230V
$1,29999
$1,23899
You save: $61.00
In stock
Price in points: 1239 points
+

Minimum quantity for "Powmr 7200W 230V AC System 48V DC Solar Inverter Charger Built-In 80A MPPT Solar Charge Controller Max PV 500V Off-Grid Inverter With Parallel 6 Units 2 MPP Tracker" is 1.

Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price

PowMr UK warehouse,AUS warehouse,USA warehouse,GER warehouse and China warehouse

Powmr 7200W 230V AC System 48V DC Solar Inverter Charger Built-In 80A MPPT Solar Charge Controller Max PV 500V Off-Grid Inverter With Parallel 6 Units 2 MPP Tracker

INTRODUCTION

This is a multi-function inverter, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support in a single package. The comprehensive LCD display offers user-configurable and easy-accessible button operations such as battery charging current, AC or solar charging priority, and acceptable input voltage based on different applications.

Features

  • Brand: Powmr
  • Product Model: POW-MAX-7.2KW-48V-230V
  • Pure sine wave inverter
  • Configurable color with the built-in RGB LED bar
  • Built-in Wi-Fi for mobile monitoring (APP is required)
  • Supports USB On-the-Go function
  • Built-in anti-dusk kit
  • Detachable LCD control module with multiple communication ports for BMS (RS485, CAN-BUS, RS232)
  • Configurable input voltage ranges for home appliances and personal computers via LCD control panel
  • Configurable AC/PV output usage timer and prioritization
  • Configurable AC/Solar charger priority via LCD control panel
  • Configurable battery charging current based on applications via LCD control panel
  • Compatible to utility mains or generator power
  • Auto restart while AC is recovering
  • Overload / Over temperature / short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function

Basic System Architecture

The following illustration shows basic application for this unit. It also includes the following devices to have a complete running system:

  • Generator or Utility mains
  • PV modules

Consult with your system integrator for other possible system architectures depending on your requirements.

This inverter can power various appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioners

Depending on different power situations, this hybrid inverter is designed to generate continuous power from PV solar modules (solar panels), battery, and the utility. When MPP input voltage of PV modules is within acceptable range (see specification for the details), this inverter is able to generate power to feed the grid (utility) and charge battery. Galvanic isolation designed between PV/DC and AC output, so that user could connect any type of PV array to this Hybrid inverter. See Figure 1 for a simple diagram of a typical solar system with this hybrid inverter.

Product Overview

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on/off switch
  7. AC input connectors and Display Panel section for details) and USB function
  8. AC output connectors (Load connection)
  9. PV connectors the details)
  10. Battery connectors
  11. Remote LCD module communication
  12. Current sharing port
  13. Parallel communication port
  14. Dry contact
  15. USB port as USB communication port and USB function port
  16. BMS communication port: CAN, RS-485 or RS-232
  17. Output source indicators (refer to OPERATION/Operation and Display Panel section for details) and USB function setting reminder (refer to OPERATION/Function Setting for the details)
  18. RS-232 communication port
  19. RGB LED bar (refer to LCD Setting section for the details)

SAFETY INSTRUCTIONS

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
  2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION – Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It’s very important to correctly operate this inverter/charger.

Please confirm the specification before install

Correct Connecting Order : Battery - solar panel - load

Disconnect : solar panel - battery - load



Possibly you may be interested
  • Bestsellers
  • Most Popular
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase