PowMr DC 48V Output AC 220V 5500W Solar Inverter Charger POW-HVM5.5K-48V
PowMr 5500W Solar Inverter 48V DC to 220V-230V AC + 80A MPPT Charge Controller
INTRODUCTION
This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger, and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers
user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger
priority, and acceptable input voltage based on different applications.
Features
Pure sine wave inverter
Inverter running without battery
Built-in MPPT solar controller
Configurable input voltage range for home appliances and personal computers via LCD setting
Configurable battery charging current based on applications via LCD setting
Configurable AC/Solar Charger priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload/ Over temperature/ short circuit protection
Smart battery charger design for optimized battery performance
Cold start function
FOUR CHARGING&THREE OUTPUT MODES
PV Module Selection
Operation and Display Panel
Specifications
INVERTER MODEL | 5.5KVA |
Rated Power | 5500W |
Max. PV Open CircuitVoltage | 500Vdc |
PV Array MPPT Voltage Range | 120Vdc~450Vdc |
Max. Input Current | 18A |
AC Charging Current (Max) | 80Amp |
Nominal Input Voltag | 230Vac |
Output Voltage Regulation | 230Vac±5>% |
Frequency | 60Hz or 50Hz |
Operating temperature range | -10°C to 55°C |
Systems Digram
NOTE:
- Do not mount the inverter on flammable construction materials.
- Before using this inverter, please read all instructions and caution marks on the unit, understand the batteryies and all sppropriate sections of its user manual.
- All wiring must be performed by a qualified personnel
- Do not disassemble the unit.
- Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are worked in parallel operation.
Line Mode Specifications | |
INVERTER MODEL | POW-HVM5.5K-48V |
Input Voltage Waveform | Sinusoidal (utility or generator) |
Nominal Input Voltage | 230Vac |
Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
Low Loss Return Voltage | 180Vac±7V (UPS); |
100Vac±7V (Appliances) | |
High Loss Voltage | 280Vac±7V |
High Loss Return Voltage | 270Vac±7V |
Max AC Input Voltage | 300Vac |
Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
Low Loss Frequency | 40±1Hz |
Low Loss Return Frequency | 42±1Hz |
High Loss Frequency | 65±1Hz |
High Loss Return Frequency | 63±1Hz |
Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits |
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) |
Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
Inverter Mode Specifications | |
INVERTER MODEL | 5.5KVA |
Rated Output Power | 5.5KVA/5.5KW |
Output Voltage Waveform | Pure Sine Wave |
Output Voltage Regulation | 230Vac±5% |
Output Frequency | 60Hz or 50Hz |
Peak Efficiency | 94% |
Overload Protection | 5s@>140% load; 10s@100%~140% load |
Surge Capacity | |
Nominal DC Input Voltage | 48Vdc |
Cold Start Voltage | 46.0Vdc |
Low DC Warning Voltage | |
@ load < 20% | 44.0Vdc |
@ 20% < load < 50% | 42.8Vdc |
@ load > 50% | 40.4Vdc |
Low DC Warning Return Voltage | |
@ load < 20% | 46.0Vdc |
@ 20% < load < 50% | 44.8Vdc |
@ load > 50% | 42.4Vdc |
Low DC Cut-off Voltage | |
@ load < 20% | 42.0Vdc |
@ 20% < load < 50% | 40.8Vdc |
@ load > 50% | 38.4Vdc |
Charge Mode Specifications | |
Utility Charging Mode | |
INVERTER MODEL | 5.5KVA |
AC Charging Current (Max) | 80Amp (@ VI/P=230Vac) |
Bulk Charging Voltage | |
Flooded Battery | 58.4Vdc |
AGM / Gel Battery | 56.4Vdc |
Floating Charging Voltage | 54Vdc |
Overcharge Protection | 63Vdc |
Charging Algorithm | |
Solar Input | |
INVERTER MODEL | 5.5KVA |
Rated Power | 5500W |
Max. PV Array Open Circuit Voltage | 500VDC |
PV Array MPPT Voltage Range | 120-450VDC |
Max. Input Current | 18A |
General Specifications | |
INVERTER MODEL | 5.5KVA |
Safety Certification | CE |
Operating Temperature Range | -10°C to 55°C |
Storage temperature | -15°C to 60°C |
Humidity | 5% to 95% Relative Humidity (Non-condensing) |
Dimension (D*W*H), mm | 448x295x105 |
Net Weight, kg | 9.9 |
- Administrator reply
- Hello, our service will contact u soon.
- Administrator reply
- Hello, our service will contact u soon.
- Administrator reply
- Hello, our service will contact u soon.
- Administrator reply
- Hello, our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will contact u soon.
- Administrator reply
- Our service will contact u soon
- Administrator reply
- Our service will reply to you soon